< WSW15 >
Selector No.
1
Redial interval
2
3
|
No. of redialings
6
7
(Not used.)
8
CRP option
- Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
- Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for
three seconds and then makes a retry three times. This CRP option is a request command
that can be sent from the called station for requesting the calling station to retry the failed
command immediately.
Function
No. 1
No. 3
App. 1-20
Setting and Specifications
2
0
0: 5 min.
0
1: 1 min.
1
0: 2 min.
1
1: 3 min.
4 5 6
0
0 0 0: 16 times
0
0 0 1: 1 times
0
0 1 0: 2 times
0
0 1 1: 3 times
|
1
1 1 1: 15 times
0: Disable
1: Enable