Brother DCP-9040CN Service Manual page 422

Hide thumbs Also See for DCP-9040CN:
Table of Contents

Advertisement

< WSW41 >
Selector No.
1
ON-duration of the scanning
|
light source at room
temperature (Not used.)
3
4
I-FAX relay report
5
|
Modem attenuator
8
- Selectors 1 through 3: ON-duration of the scanning light source at room temperature
If the scanning operation is started when the scanning light source is off, then it will come
on for scanning. These selectors determine how long the light source is ON after
scanning.
If these selectors are set to "1, 1, 1," the light source goes off immediately after the
scanning sequence.
- Selectors 5 through 8: Modem attenuator
These selectors are used to adjust the transmitting level of the modem when the reception
level at the remote station is improper due to line loss. This function applies to super G3
protocol signals.
Function
(Not used.)
App. 1-47
Setting and Specifications
No. 1
2 3
0
0 0: 16 hours
0
0 1: 24 hours
0
1 0: 12 hours
0
1 1: 8 hours
1
0 0: 4 hours
1
0 1: 2 hours
1
1 0: 10 min.
1
1 1: 0 min.
0: ON
1: OFF
No. 5
6 7 8
0
0 0 0: -10 dBm
0
0 0 1: -11 dBm
0
0 1 0: -12 dBm
0
0 1 1: -13 dBm
0
1 0 0: -14 dBm
|
1
1 1 1: -25 dBm