8.10 Transfer HVPS PCB Unit

(1) Disconnect the four Connectors from the Electrode head.
(2) Disconnect the flat cable (CN1) and two connectors (CN5, CN8) from the Registration relay
PCB unit.
Note:
- After disconnecting the flat cable(s), check that each cable is not damaged at its end or
short-circuited.
- When connecting the flat cable(s), do not insert it at an angle. After insertion, check that
the cable is not at an angle.
Transfer HVPS PCB unit
<Back side>
Fig. 3-30
Transfer HVPS PCB unit
<Back side>
Fig. 3-31
3-45
Electrode head
Connector
CN8
CN5
CN1
Registration relay PCB ASSY