RXS09/12DAVJU, RX09/12FAVJU
3.7

Removal of PCB

Procedure
Step
1. Removal of the PCB.
1
Feature of the PCB
2
Remove the screw on the
terminal board.
3
Release the 2 ground
terminals.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Procedure
 You can remove the PCB
when you disconnect the read
wires on the terminal board
without removing the electrical
box.
 PbF (Pb free brazing) is
adopted.
 See page 19 for detail.
(R7255)
(R10014)
The
earth
terminals
(R7257)
SiUS04-904