Rxs15/18/24Dvju, Rx15/18/24Fvju - Daikin FTXS09HVJU Service Manual

Inverter pair wall mounted type h-series
Hide thumbs Also See for FTXS09HVJU:
Table of Contents

Advertisement

SiUS04-904
1.4

RXS15/18/24DVJU, RX15/18/24FVJU

Connectors
PCB(1)(Control PCB) (outdoor unit)
1) S10, AC2
2) S20
3) S31, S32
4) S33, S71
5) S40
6) S51, S101
7) S80
8) S90
9) S91
10) AC1, E
11) H1, H2
PCB(2)(Power Supply PCB)
1) HL
2) HAC1, HE1
3) HE2
PCB(3)(Service Monitor PCB)
1) S52, S102
MID
1) S34, S72
2) S70
SPM
1) CN11, CN14
2) L1, L2
Other Designations
Note:
PCB(1)(Control PCB) (outdoor unit)
1) FU2
PCB(2)(Power Supply PCB)
1) FU1
2) V3
PCB(3)(Service Monitor PCB)
1) LED A
2) SW1 (S1W)
3) SW4 (S4W)
MID
1) FU201
18
Printed Circuit Board Connector Wiring Diagram
Connector for terminal strip
Connector for electronic expansion valve coil
Connector for SPM
Connector for MID
Connector for overload protector
Connector for service monitor PCB
Connector for four-way valve coil
Connector for thermistors
(outdoor air, heat exchanger, and discharge pipe)
Connector for fin thermistor
Connector for power supply PCB
Connector for diode bridge
Connector for terminal strip
Connector for control PCB
Connector for ground
Connector for control PCB
Connector for control PCB
Connector for fan motor
Connector for control PCB
Connector for reactor
Fuse (3.15A)
Fuse (30A)
Varistor
Service monitor LED
Forced operation ON/OFF switch
Local setting switch
Fuse (3.15A)
Printed Circuit Board Connector Wiring Diagram