Daikin FTXS09HVJU Service Manual page 108

Inverter pair wall mounted type h-series
Hide thumbs Also See for FTXS09HVJU:
Table of Contents

Advertisement

Service Check Function
5. Press the TEMP button.
6. Diagnose by the sound.
7. Determine the error code.
8. Press the MODE button to exit from the diagnosis mode.
9. Press the ON/OFF button twice to return to the normal mode.
When the remote controller is left untouched for 60 seconds, it returns to the normal mode.
Note:
Service Diagnosis
 or  button  and change the figure until you hear the long beep.
Press TEMP
beep: The left-side numeral is incorrect; move to the next number.
beep-beep: The right-side number is incorrect; move to the next number.
long beeeeep: Both numbers are correct; this is your error code. Refer to the troubleshooting
section to learn more about his code.
The figure indicated when you hear the long beep sound is the error code.
(Error codes and description
The display "
" means the trial operation mode.
(Refer to page 262 for trial operation.)

Refer to page 98.)