Other Considerations; Trial Operation; Other Considerations Part - Daikin FTXS09HVJU Service Manual

Inverter pair wall mounted type h-series
Hide thumbs Also See for FTXS09HVJU:
Table of Contents

Advertisement

SiUS04-904

1. Other Considerations

1.1

Trial Operation

1.1.1 Trial Operation and Testing
1. Measure the supply voltage and make sure that it falls in the specified range.
2. Trial operation should be carried out in either cooling or heating mode.
3. Carry out the test operation in accordance with the Operation Manual to ensure that all functions
 The air conditioner requires a small amount of power in its standby mode. If the system is not to
 If the circuit breaker trips to shut off the power to the air conditioner, the system backs up the
For Heat pump
In cooling mode, select the lowest programmable temperature; in heating mode, select the highest
programmable temperature.
 Trial operation may be disabled in either mode depending on the room temperature.
 After trial operation is complete, set the temperature to a normal level.
 For protection, the system disables restart operation for 3 minutes after it is turned off.
1.1.2 Trial operation from Remote Controller
(1) Press the MODE button and select operation mode.
(2) Press the ON/OFF button to turn on the system.
(3) Press the both of TEMP buttons and the MODE button at the same time.
(4) Press the MODE button twice.
(5) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a trial
254
and parts, such as louver movement, are working properly.
be used for some time after installation, shut off the circuit breaker to eliminate unnecessary
power consumption.
operation mode. The system then restarts operation with the previous mode when the circuit
breaker is restored.
(78°F to 82°F (26°C to 28°C) in cooling mode, 68°F to 75°F (20°C to 24°C) in heating mode)
("T" appears on the display to indicate that Trial Operation is selected.)
operation, press the ON/OFF button.
(1) (3) (4)

Other Considerations

(4)
(3)
(3)
(2) (5)
(R9675)
Other Considerations