RXS15/18/24DVJU, RX15/18/24FVJU
Step
2. Removal of the harnesses.
1
Remove the fixing screw
in the cable way board.
2
Push the hook up to
release the cable way
board.
Open the cable way
board.
3
Release the harnesses
from the power supply
PCB.
HL (black) ···· to the
terminal strip
HE2 (yellow / green) ···· to
the terminal strip (ground)
HAC1 (black) ···· from the
control PCB (AC1)
HE1 (yellow / green) ····
from the control PCB (E)
Removal Procedure
Procedure
SiUS04-904
Points
 Service monitor PCB
LED A (Green)
LEDA(Green)
S52
SW1
ON
SW4
A B C
SW4
(Initial setting: OFF)
(R2704)
 Power supply PCB
HE1
V3(varistor)
HE2
HL
FU1 250V 30A
(soldered)
(R2707)
HAC1
237