Fan Speed Control For Indoor Units - Daikin FTXS09HVJU Service Manual

Inverter pair wall mounted type h-series
Hide thumbs Also See for FTXS09HVJU:
Table of Contents

Advertisement

SiUS04-904
During cooling or dry mode, the louver retracts into the indoor unit, allowing cool air to blow across
the whole room.
Wide-Angle Fins
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing
The following table explains the auto-swing process for heating, cooling, dry, and fan :
 09/12 Class
 15/18/24 Class
Alternative repetition of vertical and horizontal oscillating motions enables uniform airconditioning of
Outline of 3-D
the entire room. This function is effective when starting the air conditioner.
Airflow
Detail of the
When the horizontal and vertical oscillations are both set to auto mode, the airflow becomes 3-D
airflow by alternating the horizontal vertical motions. The order of motion is such that it turns
Action
counterclockwise, starting from the right upper point as viewed from the front side of the indoor unit.
1.3

Fan Speed Control for Indoor Units

Control Mode
The airflow rate can be automatically controlled depending on the difference between the set
temperature and the room temperature. This is done through phase control and Hall IC control.
For more information about Hall IC, refer to the troubleshooting section, Fan Motor (DC Motor) or
Related Abnormality on page 102.
Phase Steps
Phase control and fan speed control contains 9 steps: LLL, LL, SL, L, ML, M, MH, H and HH.
In automatic operation, the step "SL" is not available.
Function and Control
Horizontal blades (louvers) with Vertical Swing (up and down)
Cooling / Dry
25˚
25˚
(R2946)
Horizontal blades (louvers) with Vertical Swing (up and down)
Heating
Cooling
10˚
15˚
15˚
40˚ 10˚
55˚
55˚
(R2813)
Step
Heating / Fan
30˚ 5˚
30˚
(R4013)
Dry
35˚
40˚
35˚
(R2814)
(R2815)
Cooling
Heating
Main Functions
Vertical blades (fins) with
Horizontal Swing
(right and left: manual)
Heating, Cooling
(R2817)
Vertical blades
(fins) with
Horizontal Swing
(right and left)
Fan
Heating, Cooling
55˚
55˚
(R2816)
(R1024)
(R2817)
25