• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the
precautions below: they are all important for ensuring safety.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION
Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
DANGER
• Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially
in basements, and an asphyxiation hazard could occur leading to serious injury or death.
• If the refrigerant gas leaks during installation, ventilate the area immediately.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas could cause severe injury or death.
• After completing the installation work, check that the refrigerant gas does not leak.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device. Exposure to this gas could cause severe injury or death.
• Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a severe shock hazard
resulting in severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.
• Safely dispose of the packing materials.
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear apart and throw away plastic packaging
bags so that children will not play with them. Children playing with plastic bags face the danger of death by suffocation.
• Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death.
• Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard resulting in
severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death.
WARNING
• Installation should be left to the authorized dealer or another trained professional.
Improper installation may cause water leakage, electrical shock, fire, or equipment damage.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, fire or equipment damage.
• Be sure to use the supplied or exact specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, fire or equipment damage.
• Install the air conditioner on a solid base that is level and can support the weight of the unit.
An inadequate base or incomplete installation may cause injury or equipment damage in the event the unit falls off the base or comes loose.
• Electrical work should be carried out in accordance with the installation manual and the national, state and local electrical wiring codes.
Insufficient capacity or incomplete electrical work may cause electrical shock, fire or equipment damage.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
Follow all appropriate electrical codes.
• For wiring, use a wire or cable long enough to cover the entire distance with no splices if possible. Do not use an
extension cord. Do not put other loads on the power supply. Use a only a separate dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock, fire or equipment damage.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units. Follow all state and local electrical codes.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating, fire or equipment damage.
• After connecting all wiring be sure to shape the cables so that they do not put undue stress on the electrical covers, panels or terminals.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock,fire or equipment damage.

Safety Precautions

Be sure to establish an earth
connection.
3P232730-1 M08B055
Two-dimensional bar code
is a code for manufacturing.
Never attempt.

Advertisement

Table of Contents
loading

Summary of Contents for Daikin M08B055

  • Page 1: Safety Precautions

    3P232730-1 M08B055 DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety.
  • Page 2: Choosing A Site

    Safety Precautions WARNING • When installing or relocating the system, be sure to keep the refrigerant circuit free from all substances other than the specified refrigerant (R410A), such as air. (Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise which may result in rupture, resulting in injury.) •...
  • Page 3: Indoor Unit Installation Drawings

    Indoor Unit Installation Drawings ■ How to attach the indoor unit. A Mounting plate B 3/16” × 1”L Hook the claws of the bottom (M4 × 25mm) A Mounting frame to the mounting plate. plate If the claws are difficult to hook, remove the front grille.
  • Page 4: Installation Tips

    Installation Tips 1. Removing and installing front panel. If it is difficult to remove, open the front grille and raise the • top grid, using a screwdriver, to unhook the hooks. Removal method Raise and Upper hook Hook fingers on the panel protrusions on the left and right remove Upper grille Hook...
  • Page 5: Installing Indoor Unit

    Indoor Unit Installation (2) Boring a wall hole and installing wall embedded pipe. Inside Outside • For walls containing metal frame or metal board, be sure to use a wall Wall embedded pipe (Field supply) Caulking embedded pipe and wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire.
  • Page 6: Drain Piping

    Indoor Unit Installation (3) 3-3. Wall embedded piping. Insert drain hose Inner wall to this depth so Follow the instructions given under it won’t be pulled out of drain pipe. Left-side, left-back, or left-bottom piping 1-15/16” Drain hose (50mm) or more Vinyl chloride 1) Insert the drain hose to this depth so it won’t be drain pipe...
  • Page 7: Refrigerant Piping Work

    Refrigerant Piping Work Check Flaring the pipe end. The pipe end must Flare’s inner be evenly flared in 1) Cut the pipe end with a pipe cutter. surface must a perfect circle. (Cut exactly at be flaw-free. 2) Remove burrs with the cut surface facing right angles.) Remove burrs Make sure that the...
  • Page 8: Run Test And Final Check

    Run Test and Final Check Trial operation and testing. 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. • In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable temperature.