DigiDesign VENUE Profile Manual page 251

Venue d-show 2.8.1
Table of Contents

Advertisement

GPI Input Connector Pin Assignments
The D-Show Profile GPI Input is a male DB-25 connector.
GPI Input Connector Pin Assignments
Pin Number
Function
1
Input 1
2
Input 2
3
Input 3
4
Input 4
5
Input 5
6
Input 6
7
Input 7
8
Input 8
14, 15, 16, 17, 18,
Ground
19, 20, 21
9, 10, 11, 12, 13, 22,
Reserved
23, 24, 25
Pinout for GPI Input Connector
1
2
3 4
5
6
7
14 15 16 17 18 19 20 21 22 23 24 25
Pinout for Profile DB25M GPI Input port (looking at back of console)
Comments
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
Logic level (TTL, CMOS)
input with pullup
All ground pins are con-
nected together inter-
nally
Do not use
8
9 10 11 12 13
GPI Output Specifications
A 25-pin, female D-Sub connector provides a total of 8 Gen-
eral Purpose Interface (GPI) Outputs.
• Outputs are isolated, floating relay contacts (contact clo-
sure).
• Switched voltage is 200V max; 0.5A max.
• Switched voltage with respect to safety/chassis ground is
300V max.
The Profile GPI Outputs can switch 500 mA maximum.
This applies even to short term current surges. This limit
can be exceeded when driving a capacitive or incandescent
lamp load. An incandescent lamp may draw as much as
ten times its steady state current when first turned on.
Therefore such lamps are typically not appropriate loads for
the GPI Outputs, and should instead be controlled by a sec-
ondary relay.
GPI Output Power Specification
The GPI Output connector also provides +12VDC at up to 200
mA for powering external devices, such as relays or LEDs. The
ground return that is provided is the D-Show Profile internal
system ground, which is connected to AC safety ground.
GPI Output Ground Connections
The GPI Outputs provided are isolated contact-closure style.
Each GPI output is presented on a pair of pins (see "GPI
Output Connector Pin Assignments" on page 242). These two
pins represent the two sides of a switch that can be opened
and closed. If it is desired to drive a signal to ground, then one
of the pins must be wired to ground, and the other to the
signal to be controlled.
Chapter 29: Control Surface Reference 241