Lenovo ThinkServer TS430 Hardware Maintenance Manual page 91

Machine types: 0387, 0388, 0389, 0390, 0391, 0392, 0393, and 0441
Hide thumbs Also See for ThinkServer TS430:
Table of Contents

Advertisement

1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 76.
2. On the main interface of the program, select Initialize and follow the instructions on the screen.
Setting a hot-spare drive
This topic provides instructions on how to set a physical drive as a hot-spare drive using the LSI Software
RAID Configuration Utility program.
A hot-spare drive is an extra, unused drive that is part of the disk subsystem. It is usually in standby
mode and ready for service if a drive fails. Setting hot-spare drives enables you to replace failing drives
without performing a system shutdown operation. For a detailed introduction to hot-spare drives, refer to
"Introduction to RAID" in the MegaRAID SAS Software User Guide on the documentation DVD that comes
with your server.
To set a physical drive as a hot-spare drive using the LSI Software RAID Configuration Utility program,
do the following:
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 76.
2. Do one of the following:
• If you want to create or add a new RAID array, you can set a hot-spare drive during the configuration
process by following the instructions on the screen.
• If you want to set a hot-spare drive right after the configuration, select Objects ➙ Physical Drive
from the program main interface. Then, select the physical drive that you want to set as a hot-spare
drive and press Enter. A submenu is displayed. Select Make Hot Spare from the submenu and then
select Yes when prompted to set the physical drive as a hot-spare drive.
Rebuilding a physical drive
This topic provides instructions on how to rebuild a physical drive using the LSI Software RAID Configuration
Utility program when a physical drive in an array fails.
When a drive in a RAID drive group fails, you can rebuild the drive by recreating the data that was stored on
the drive before it fails. If the drive is not operational, it must be replaced and the data on the failing drive
must be rebuilt on a new drive to restore the system to fault tolerance. If hot-spare drives are available, the
failing drive might be rebuilt automatically without any user intervention.
The RAID controller recreates the data using the data stored on other drives in the drive group. Rebuilding
can be done only in drive groups with data redundancy, such as RAID 1, 5, and 10 drive groups. For a
detailed introduction to disk rebuild, refer to "Introduction to RAID" in the MegaRAID SAS Software User
Guide on the documentation DVD that comes with your server.
To rebuild a physical drive using the LSI Software RAID Configuration Utility program when a physical
drive in an array fails, do the following:
1. Start the LSI Software RAID Configuration Utility program. See "Starting the LSI Software RAID
Configuration Utility program" on page 76.
2. On the main interface of the program, select Rebuild and follow the instructions on the screen.
Note: Running a consistency check immediately after the rebuild completes to ensure data integrity for the
virtual drives. See "Running a consistency check" on page 80.
The rebuild rate is the percentage of the computing cycles dedicated to rebuilding failing drives. A rebuild
rate of 100 percent means that the system gives priority to rebuilding the failing drives. The rebuild rate can
.
Chapter 5
Configuring the server
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

038703910392039304410388 ... Show all

Table of Contents