Lenovo ThinkServer TS430 Hardware Maintenance Manual page 172

Machine types: 0387, 0388, 0389, 0390, 0391, 0392, 0393, and 0441
Hide thumbs Also See for ThinkServer TS430:
Table of Contents

Advertisement

5. Press the two tabs of the front system fan towards each other until the two tips
corresponding holes in the chassis. Then, carefully slide the front system fan out of the chassis.
Figure 94. Removing the front system fan
6. Touch the static-protective package that contains the new front system fan to any unpainted surface on
the outside of the server. Then, remove the new front system fan from the package.
7. Position the new front system fan on the system fan 1 mounting area of the chassis so that the three tips
1
on the bottom of the front system fan are aligned with the corresponding holes in the mounting area.
Meanwhile, make sure that the two posts
holes in the inner side of the chassis. Then, carefully slide the front system fan into the chassis until
it snaps into position.
Figure 95. Installing the front system fan
160
ThinkServer TS430 Hardware Maintenance Manual
2
of the front system fan are aligned with the corresponding
1
are aligned with the