Extending/Replacing The Main Memory - Fujitsu Siemens Computers PRIMERGY TX200 S3 Options Manual

Hide thumbs Also See for PRIMERGY TX200 S3:
Table of Contents

Advertisement

Extending/replacing the main memory

– The module capacity between pairs can differ: pair 1A/1B can be populated
with two 512 Mbyte modules and pair 2A/2B with two 1 Gbyte modules.
The table below shows the order in which the memory banks must be equipped:
module pair 1A/1B
(black)
populated
populated
populated
5.2
Extending/replacing the main memory
Ê Open the server as described in the
Figure 12: Removing the ventilation duct over the main memory
Ê Press the green touch point of the latch (1) in the direction of the arrow.
Ê Lift out the ventilation duct over the main memory.
28
module pair 2A/2B
(blue)
empty
populated
populated
1
Options Guide
module pair 3A/3B
(blue)
empty
empty
populated
chapter "Preparation" on page
Main memory
19ff.
TX200 S3

Advertisement

Table of Contents
loading