Installing the SCSI hard disks extension
box
In the SCSI base units the two upper bays can be used to install a SCSI hard
disks extension box.
Ê Open the server and remove the front cover or rack front cover as described
in the
chapter "Preparation" on page
I
TheSCSI hard disks extension box is supplied without EasyClick rails.
Before installing a new hard disks extension box you must therefore
remove the EasyClick rails from one of the two dummy covers and mount
the EasyClick rails on the hard disks extension box.
Ê Remove the dummy covers from the two upper 5.25-inch bays for accessible
drives:
Ê Press the two metal tongues of the EasyClick rails inward (1) until the
locking mechanism is released.
Ê Remove the dummy cover from the bay.
Ê Remove the EasyClick rails from one of the dummy covers by removing the
four screws on each side.
I
Note that there are two M3 screws and two UNC screws on each side.
V
CAUTION!
Keep the dummy covers for future use. If you remove the hard disks
extension box again and do not replace it with new drives, the dummy
covers must be reinstalled to comply with EMC regulations and to
satisfy cooling requirements and fire protection measures.
TX200 S3

Installing the SCSI hard disks extension box