Install a lightwave transceiver on the media gateway connector at the position in the TO column
in the running list.
6
Route the cables from the FROM media gateway down into the cable trays of each PN media
gateway. Connect the cables to the lightwave transceiver just installed on the TO media gateway.
7
Connect the fiber that comes from the TX connector of the FROM transceiver to the RX
connector of the TO transceiver and vice versa.
8
Route the cables through the media gateway and through cable organizers as provided. Secure the
cables to the cable-tie rack.
Connecting duplex- or high-reliability
center stage switch-connected PN1 with one
switch node
Figure 37, Duplex- or high-reliability CSS-connected PN1 with one switch node,
typical fiber optic cabling between media gateways. The cable between the EI and SNI on PN1 is a pre-
installed metallic cable (H600-278).
1
If no running list is available, use the outer slots first in alternating order. Connect the first two
SNI slots to 3 and 20 (the left most and right most of the unused slots). Next, use 4 and 19, and so
forth.
2
Add links to the PNs in alternating order (20, 3, 19, 4, 18, 5, and so forth).
124
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
on page 125 shows