12
•
Figure 6: Input and Output
WARNING: Ensure that all
power (irrespective of cabl
Connector.
2
.2.
1 LED Status Indicator
The camera is equipped w
the c
corresponding LED states.
When m
priorit
describing t
Table 3: Status LED
Flashing Green
Solid Green
Flashing Red
Solid Red
2.2.2 Camera Link Data Connector
Figure 7: Camera Link MDR26 Connector
13
26
Cable: 3M 14X 26-SZ LB-X X X -0LC* *
The Camera Link interface is implemented as either a Base or Medium Configuration in
the stop action 4M cameras. You select the camera configuration with the
described in section 3.3.2 Setting the Camera Link Mode .
03-32-10121-09
PRELIMINARY
One 6-pin Hirose connector for power. Re
details.
CONTROL
DATA 1
DATA 2
POWER
the correct voltages at full load are present at the camera end of the
e length) according to the pinout defined in section 2.2.3 Power
ith a red/green LED used to display the operational status of
ame
ra. The table below summarizes the operating states of the camera and the
ore tha
n one condition is active, the
y. Error
and warning states are accompanied by correspond
he current
camera status.
Camera initialization or executing a time consuming command
Camera is operational and functioning correctly
Fatal Error. System voltage out of tolerance.
Warning. Loss of functionality (e.g. external SRAM failure)
MDR26 Female
M at ing Par t: 3M 334-31 ser ies
fer to section 2.2.3 Power Connector for
Diagnostic LED
Camera Link (Base Configuration)
Camera Link (Medium Configuration)
+12V to +15V
LED indicate
s the con
1
14
4M Stop Action Camera Manual
dition with the highest
ing messages further
command
clm
DALSA