Hardware Installation
Connecting the keyboard, mouse and monitor
Ê Connect the monitor, the keyboard and mouse to the standard ports of the
server (see figure 22 on page 47 and figure 23 on page 48).
I
If a separate graphics card is installed in a slot, the graphic controller on
the system board is automatically deactivated. The corresponding
monitor port can not be used. Plug the data cable of the monitor into the
monitor port of the graphics card.
Ê Connect the power cable of the monitor to a grounded mains outlet of the in-
house mains and/or into the mains socket strip of the rack.
V
CAUTION!
The rated current for the monitor can be found on the technical data label
on the monitor or in the operating manual for the monitor.
4.6

Connecting the Server to the Line Voltage

In its basic configuration level the server has a fixed power supply unit.
As an option, this power supply unit can be replaced with a hot-plug power
supply unit. A second hot plug power supply unit can be added to achieve
redundant power supply. If a defect occurs in one power supply unit, the
respective other power supply unit ensures unimpaired further operation.
V
CAUTION!
The server automatically adjusts to a mains voltage between
100 - 127 V and/or 200 - 240 V. The server may be place in operation
only, if the mains voltage range set on the server corresponds to the local
mains voltage.
A26361-K879-Z102-3-7619
Connecting the Server to the Line Voltage
49