Additional
Specifications
Rise Time (No Load, Full Load):
Fall Time (No Load):
Fall Time (Full Load):
Voltage Mode Transient Response:
Time Delay from power on until
output stable
1.
2.
Input
Conditions
Rated AC Input Voltage with
Maximum Input Current
Maximum AC Input Power
Operational AC Input Voltage
Input Frequency Range
Power Factor
Additional
Features
Switching Frequency
Output Hold-up Time
Maximum Voltage Differential from
either output to safety ground
Insulation Resistance
Isolation Voltage
1.
Release 2.2
1
1
Measured with stepped 0-10 V analog programming source and a resistive load.
Time for the output voltage to recover within 1% band for 30% step load change from
70% to 100% or 100% to 70%.
To protect from power surges, the units have a 420 Vac varistor built in to act as an
over-voltage clamp. The above insulation resistance specification is subject to be
measured with the varistors taken out of the circuit
1
300 ms (full load and no load)
5 s
200 ms
2
1 ms
2 s maximum
200-250 Vac at 10 Arms or 100-130 Vac at
20 Arms
1300 W at full load
200-250 Vac or 100-130 Vac
47-63 Hz
approx. 0.7 at full load
Nominal 100 kHz, 200 kHz output ripple
>80 V models: 80 kHz, 160 kHz output ripple
15 ms at full load, nominal line
±600 Vdc
Input to chassis: >30 MΩ, with 500 Vdc;
Output to chassis: >20 MΩ, with 1000 Vdc.
Input to output: 1350 Vac
Features and Specifications