1. Front output current limited to 30 A maximum.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0 to 100% load variation, with constant nominal line voltage (rear output only).
4. Current mode noise is measured from 10% to 100% of rated output voltage, full current, resistive load.
5. Maximum drift over 60 minutes with constant line, load, and temperature, after power on.
6. Maximum drift over 8 hours with constant line, load, and temperature, after 60-minute warm-up.
7. Change in output per ° C change in ambient temperature, with constant line and load.
8. Typical efficiency is measured at 120 V and full output power.
Additional Specifications
Rise Time (No load, full load)
Fall Time (Full load)
Fall Time (No load)
Voltage Mode Transient Response
Time delay from power on until output stable
Input Conditions
Rated AC Input Voltage
Maximum AC Input Power
Operational AC Input Voltage Range
Maximum Input Current
Input Frequency Range
Power Factor
Input Harmonic Distortion
Release A
Section 1. Features and Specifications
50 ms
50 ms
400 ms
1 ms
3 s maximum
100/120/200/230/240 Vac, universal input
700 W
85 to 264 Vac; power factor corrected
7 A maximum at 100 Vac, 6 A maximum at
120 Vac, 3 A maximum at 220 Vac
47 to 63 Hz
0.98 minimum for full load at nominal
voltage
Current harmonics meet IEC 1000-3-2