Alcatel Speed Touch 591s Technical User's Manual page 55

Shdsl router
Table of Contents

Advertisement

Table 5-1 lists the user port parameters that can be configured.
Parameter
Name
Clock rate
Interface type
Clocking mode
Clock inversion
Control leads
Note
(1)
When the test mode lead is set to Ind_maint, it is controlled by software-initiated maintenance. The
lead is forced on when a maintenance action such as a loopback is applied to the unit, and it is forced
off when all maintenance actions are removed.
Procedure 5-1 Naming the user port
CONFIG — OBJECT — PORT — <U>
where name contains a maximum of 15 characters excluding space, tab, period, question
mark, and percent sign
Speed Touch 591s Technical Practices
February 2001
90-8785-01
5 — Configuring frame relay port parameters
Table 5-1 User port parameters
Options
15-character string
9.6, 19.2, 48, and
n
64 (n = 1 to 32)
V.35, V.36/TIA/EIA-449,
X.21
DCE slave, DCE external
(V35/V36 only)
Enable, Disable
C
Active, Assume On,
(X.21)
Assume Off
DTR
Active, Assume On,
(V.35/V.36)
Assume Off
RTS
Active, Assume On,
(V.35/V.36)
Assume Off
DSR (V.35/V.36)
Force On, Force Off
DCD (V.35/V.36)
Active, Force On, Force
I (X.21)
Off
CTS (V.35/V.36)
Active, Force On, Force
Off
TM (V.35)
Force On, Force Off,
Ind_maint
— NAME — <name>
Default value
512 kb/s
V.35
DCE slave
Disable
Active
Active
Active
Force On
Active
Active
Ind_maint
(1)
5-3