{ACN - MIDI Rx ID(s)}
This setting allows you to specify the MIDI Show Control data that your console will receive when
transmitted over the Architecture for Control Network (ACN). When set, the console will respond to
MSC data from any gateway that has its "ACN MIDI Rx ID" set to the same number. ACN MIDI Rx
ID can be from 1-32. ID ranges may be used. When using the local MIDI ports on Eos Ti, Gio, Ion,
or Element, this setting needs to match the MIDI Rx Group ID in the ECU>{Settings}>{Local I/
O}>Show Control Gateway>Group IDs.For example:
• {ACN MIDI Rx ID} [2] [5] [Enter]
• {ACN MIDI Rx ID} [1] [Thru] [1][0] [Enter]
{MSC Transmit}
This setting, when enabled, allows the console to send MSC messages for actions taken on the
console, such as cue actions, macros firing, and submaster bumps. The default setting is
"Disabled".
{MSC Transmit Channel}
Also know as "Device ID" this setting allows you to establish the device ID with which your console
will transmit MIDI Show Control information. A device ID can be from 0-126, or if set to 127, Eos,
Eos Ti, Gio, Ion, or Element will transmit MSC data to all IDs (All Call). For example:
• {MSC Transmit Channel} [5] [0] [Enter]
{ACN - MIDI Tx ID}
This setting allows you to specify the ID number of MIDI Show Control data that the console
transmits over an Architecture for Control Network (ACN). When set, the console will transmit MSC
data to any gateway that has its "ACN MIDI Tx ID" set to the same number. ACN MIDI Tx ID can be
from 1-32. When using the local MIDI ports on Gio, Ion, or Element, this setting needs to match the
MIDI Tx Group ID in the ECU>{Settings}>{Local I/O}>Show Control Gateway>Group IDs. For
example:
• {ACN MIDI Tx ID} [2][5] [Enter]
{String MIDI TX}
When enabled, this setting will cause the console to send serial strings instead of a MIDI Show
Control message when certain actions happen at the console.
{MIDI Cue List}
MIDI Cue List specifies the cue list that the console will use to send MSC data. If left blank and MSC
Tx is enabled, all cue lists will generate MSC events. Otherwise, only the particular list (or lists)
selected will fire MSC events.
{Analog Inputs}
This is a master setting for receiving analog inputs from a Net3 I/O Gateway or the local analog
ports on a Gio, Ion, or Element. When disabled it will turn off all analog input for all event lists.
Default is "Enabled".
{Relay Outputs}
This is a master setting for triggering external relays from a Net3 I/O Gateway or the local ports on
a Gio, Ion, or Element. When disabled it will turn off all external relays for all event lists. The default
is "Enabled".
{String RX}
This setting will enable receiving strings on all Serial RX formats.