ETC Lighting Control Console User Manual page 248

Lighting control console
Table of Contents

Advertisement

B a c k u p A u t o m a t ic a l l y T a k e s C o n t r o l
Switches to the backup automatically if the primary should go offline. This option is not available
on Element.
A l l o w e d O u t p u t A d d r e s s e s
A range or ranges of addresses that can be assigned to limit the number of output addresses. The
default setting is to allow addresses 1 through 65536.
I n t e r f a c e P r o t o c o l s
M u lt i C on s o l e
Clicking in the enable box will allow for multiconsole communication on the selected port. For
Element, this is used to allow mirror mode.
Network Type
This setting adjusts the timeout period before a backup device will take control from the master.
• Standard - After five seconds of no response from the master, the backup will assume the
master has disconnected and will then take control.
• Engineered - After 1.6 seconds of no response from the master, the backup will assume the
master has disconnected and will then take control.
E n a b l e S e n s o r F e e d b a c k
Clicking in the enable box will allow Element to receive feedback over the network from a CEM+ or
a CEM3. This option is "Enabled" by default.
E n a b l e R D M
Clicking in the enable box will allow Element to perform RDM functionality including device
discovery. See
N o t e :
E n a b l e F D X F e e d b a c k
Clicking in the enable box will allow Element to receive FDX dimmer feedback over the network.
Broadcast Type
• Directed Broadcast - Broadcast packets are directed to a subnet based on the IP address
and subnet mask of the sender.
• Limited Broadcast - The limited broadcast address is 255.255.255.255. It is limited because
routers will never forward datagrams with that destination address. This means that
datagrams with the limited broadcast address are confined to the particular network segment
on which they originate.
E n a b l e W i F i R F R
Select to allow WiFi RFRs, like the iRFR or aRFR, to connect to Element. For additional
information, including setup, please visit the
Wiki,
www.etcconnect.com/wiki.
UD P Strings
Clicking in the enable box will allow the selected port to send UDP strings.
236
{Patch} Display and Settings, page 61
RDM requires use of a Net3 Gateway using version 5.1 or higher.
See "About Address" on page 173.
and
About Address, page
iRFR Documentation Wiki
173.
and
aRFR Documentation
Element User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Element

Table of Contents