Page 1
Fresnel User Manual Version 1.1.0 Part Number: 7470M1200-1.1.0 Rev: B Released: 2020-10...
Page 2
To view a list of ETC trademarks and patents, go to etcconnect.com/ip. All other trademarks, both marked and not marked, are the property of their respective owners. ETC intends this document, whether printed or electronic, to be provided in its entirety.
Table of Contents Introduction Help from ETC Technical Services Safety Overview Fixture User Interface Set Up and Focus the Fixture Mount the Fixture Add Accessories Connect Power and Data Focus the Fixture Use Fixture in DMX Mode Set DMX Address Set DMX Mode Set DMX Loss Behavior Use Fixture in Stand-alone Mode...
Page 4
Export Fixture Data for Troubleshooting Restore Default Settings Update Firmware Backup and Restore the Fixture Configuration Clean the Lens Specifications and Reference Environment Dimensions and Weight Electrical RDM Parameters Fixture Compliance Wireless Radio Compliance Licensed Software fos/4 Fresnel User Manual...
Introduction The fos/4 Fresnel is a shapable wash light with top quality, highly tunable output. The fos/4 Fresnel is available in two array types: Lustr X8: The next generation of the Lustr color system incorporates deep red into the •...
Help from ETC Technical Services If you are having difficulties and your problem is not addressed by this document, try the ETC support website at support.etcconnect.com or the main ETC website at etcconnect.com. If none of these resources are sufficient, contact ETC Technical Services directly at one of the offices identified below.
SAVE THESE INSTRUCTIONS Note: The light source in this luminaire is not user-replaceable, and must be replaced only by a qualified technician. Contact ETC Customer Support for assistance. WARNING: Note the following safety warnings before use: Use the fixture in dry locations only, where humidity does not exceed •...
Page 8
Si le cordon d’alimentation (câble) est abîmé, il doit être remplacé. N’utilisez pas ce projecteur si la lentille présente des rayures ou des • fissures profondes. Il faut remplacer la lentille si elle est abîmée. fos/4 Fresnel User Manual...
Overview Fixture Accessory holder: Insert accessories into the two available slots from either side of the holder, and then lock the holder. See Add Accessories on page 7 Yoke tilt-lock: Tilt the fixture as needed, and then turn the tilt-lock clockwise to lock the position.
USB port: Use for updating firmware, saving and loading fixture configuration settings, or saving error logs via a flash drive. See Troubleshooting and Maintenance on page 20 UI lock: Set this switch to lock the UI. This prevents inadvertent changes to the UI. See Lock the Display on page 19 fos/4 Fresnel User Manual...
Set Up and Focus the Fixture WARNING: Note the following safety warnings before use: Only use mounting hardware that is rated for the total weight of the • fixture and accessories. In addition to primary suspension, attach a safety cable (or other •...
Maximum fixture output may be reduced when the fixture is connected to battery power. Focus the Fixture Apply power to the fixture, and wait until the fixture has booted up (the ETC splash screen displays during boot up). Press any encoder to "wake" the display.
Use Fixture in DMX Mode After you connect power and data to the fixture and provide DMX, press the Function button ( repeatedly to toggle to the DMX screen, where you can set the DMX address, DMX mode, and DMX loss behavior. (You can also set these values using RDM.) The DMX screen displays the current DMX values.
DMX Control Channels Parameter DMX Value Description Comments 3200 K 1–165 1900–6000 K CCT values increase by 25 for each DMX value (1 = 1900 K, 2 = 1925 K, etc.). 166–254 6050–10,450 K CCT values increase by 50 for each DMX value (166 = 6050 K, 167 = 6100 K, etc.). 5600 K fos/4 Fresnel User Manual...
Page 15
Parameter DMX Value Description Comments Curve 0–9 Incandescent 10–19 Linear 20–29 Incandescent Red Shift In Direct Mode, the fixture uses Incandescent instead of Incandescent Red Shift. 30–39 Linear Red Shift In Direct Mode, the fixture uses Linear instead of Linear Red Shift.
HLL: Hold last look until you make local changes. This is the default setting. • Preset 12: Two-second fade from last look to Preset 12. • fos/4 Fresnel User Manual...
Press the Intensity encoder to toggle between the current intensity and 0%. If the fixture is connected to other fos/4 Fresnel fixtures that are in the same stand-alone mode, the connected fixtures will play the same preset or effect.
The display shows a three-second countdown before re-recording the preset. Note: The CCT, Tint, and Tune values match the values that are available when the DMX mode is set to Studio. See DMX Control Channels on page 10. fos/4 Fresnel User Manual...
Color Mode Press the Function button ( ) until the display shows the Color screen. Turn to adjust intensity, or press to toggle between current intensity and 0. Color Color I: 97% I: 97% Page 1 Page 2 Turn the green or blue encoder to Press and hold an encoder to Turn the red encoder to move modify the value in the matching field.
(for the OK icon ) to continue. Note: Changes that you make to presets in the Preset screen also affect presets in the Color screen and the Effects screen. fos/4 Fresnel User Manual...
Effects Mode Press the Function button ( ) until the display shows the Effects screen. Turn an encoder to modify the value in the matching field. Effects Settings Max Int 100% Max Int 100% Effect TV Set Style Custom Rate Step Preset Turn to select effect,...
(You must be within Bluetooth range of the Multiverse transmitter or gateway in order to use the app in this mode.) Visit etcconnect.com/Apps more information about the Set Light app. fos/4 Fresnel User Manual...
Control and Customize the Display UI Lock Lock the Display Set this switch to lock the UI and prevent any changes to the fixture setup. The display indicates when the UI is locked. Effects Max Int 100% Effect Flicker Adjust the Display Backlight Rate and Display Timeout Press the Menu button (...
Troubleshooting and Maintenance Troubleshooting Checklist If you cannot find the resources that you need in this document, contact ETC Technical Services (see Help from ETC Technical Services on page 2 What I'm Seeing What Might Be Wrong What To Try Color on the fixture does...
(overriding any other instructions to the fixture) until you return to the Test screen and exit it. View Diagnostic Data As part of troubleshooting any issues with a fixture, ETC Technical Services may ask that you view diagnostic data on the fixture. Press the Menu button ( ), turn the Intensity encoder to navigate to Diagnostics, and then press the Intensity encoder to select it.
Export Fixture Data for Troubleshooting As part of troubleshooting any issues with a fixture, ETC Technical Services may ask that you export fixture data to a USB flash drive and then send the data for further analysis.
Copying the files to the fixture: A progress meter displays as the files are copied to the fixture. Verifying the files: The ETC logo displays on the top half of the screen as the fixture verifies the files. You can safely remove the USB drive at this time.
Clean the Lens Clean the lens using a clean, micro-fiber cloth. You can use isopropyl alcohol on the cloth, but do not spray the cleaning solution directly onto the lens or into the interior of the fixture. fos/4 Fresnel User Manual...
Specifications and Reference For full product specifications, see the fos/4 Fresnel datasheet at etcconnect.com. Environment The fos/4 Fresnel operates in ambient temperatures of 0°C–40°C (32°F–104°F) and is rated IP20 (for use in dry locations only). Fixture temperature information: Maximum recommended ambient operating temperature: Ta=40°C (104°F) •...
EU Declaration of Conformity This product complies with the Essential requirements of the R&TTE Directive of the European Union (1999/5/EC). This product conforms to the following standards: ETSI EN 300 328 V1.8.1 (2012-06) • ETSI EN 301-489-1 V1.9.2 (2011-09) • ETSI EN 301-489-17 V2.2.1 (2012-09) •...