Analog Input / Input Change (Objects 30/32) - GE 489 Instruction Manual

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6 COMMUNICATIONS
In the following table, the Format column indicates that the associated data point format is determined by the entry in Table
6–2: Data Formats on page 6–34. For example, an "F1" format is described in that table as a (16-bit) unsigned value with-
out any decimal places. Therefore, the value read should be interpreted in this manner. Many of the values reported by the
489 have a size of 32-bits and have had their upper and lower 16-bit components assigned to separate points. Where indi-
cated, refer to the appropriate note following the table for more detail.
Table 6–8: ANALOG INPUTS POINT LIST (SHEET 1 OF 4)
INDEX
FORMAT
DESCRIPTION
0
F133
Generator Status
1
F1
Generator Thermal Capacity Used
2
F1
Estimated Trip Time On Overload (seconds, 65535 means never)
3
F134
Cause Of Last Trip
4
F19
Time Of Last Trip (Upper 16 Bits)
5
F19
Time Of Last Trip (Lower 16 Bits)
6
F18
Date Of Last Trip (Upper 16 Bits)
7
F18
Date Of Last Trip (Lower 16 Bits)
8
F1
Tachometer Pre-Trip
9
F1
Scale factor for pre-trip current readings (pre-trip points marked with
"Note 6"). Will always be a power of 10 (1, 10, 100, etc.). Changes only
when the configuration setpoints are changed.
10
F1
Phase A Pre-Trip Current
11
F1
Phase B Pre-Trip Current
12
F1
Phase C Pre-Trip Current
13
F1
Phase A Pre-Trip Differential Current
14
F1
Phase B Pre-Trip Differential Current
15
F1
Phase C Pre-Trip Differential Current
16
F1
Pre-Trip Negative Sequence Current
17
F1
Ground Current Scale Factor. Will always be a power of 10 (1, 10, 100,
etc.). Changes only when the configuration setpoints are changed.
18
F6
Pre-Trip Ground Current (scaled according to previous setpoint)
19
F1
Phase A-B Pre-Trip Voltage
20
F1
Phase B-C Pre-Trip Voltage
21
F1
Phase C-A Pre-Trip Voltage
22
F3
Pre-Trip Frequency
23
F1
Pre-Trip Real Power (MW)
24
F1
Pre-Trip Real Power (kW)
25
F1
Pre-Trip Reactive Power (Mar
26
F1
Pre-Trip Reactive Power (kvar)
27
F1
Pre-Trip Apparent Power (MVA)
28
F1
Pre-Trip Apparent Power (kVA)
29
F1
Last Trip Stator RTD
30
F4
Last Trip Hottest Stator RTD Temperature (°C)
31
F1
Last Trip Bearing RTD
32
F4
Last Trip Hottest Bearing RTD Temperature (°C)
33
F1
Last Trip Other RTD
34
F4
Last Trip Hottest Other RTD Temperature (°C)
35
F1
Last Trip Ambient RTD
36
F4
Last Trip Hottest Ambient RTD Temperature (°C)
37
F12
Pre-Trip Analog Input 1
GE Multilin

6.5.4 ANALOG INPUT / INPUT CHANGE (OBJECTS 30/32)

489 Generator Management Relay
6.5 DNP POINT LISTS
EVENT CLASS
NOTES
ASSIGNED TO
Class 1
Note 3
Class 1
Class 1
Class 1
Note 3
Class 1
Notes 3,4
Class 1
Notes 3,4
Class 1
Notes 3,4
Class 1
Notes 3,4
Class 1
Note 3
Class 1
Note 3
Class 1
Notes 3, 6
Class 1
Notes 3, 6
Class 1
Notes 3, 6
Class 1
Notes 3, 6
Class 1
Notes 3, 6
Class 1
Notes 3, 6
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Notes 3,8
Class 1
Notes 3,8
Class 1
Notes 3,8
Class 1
Notes 3,8
Class 1
Notes 3,8
Class 1
Notes 3,8
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Note 3
Class 1
Notes 3,9
6-47
6

Advertisement

Table of Contents
loading

Table of Contents