6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (SHEET 22 OF 24)
ADDR NAME
2C58
ANALOG INPUT2 TRIP PICKUP
2C59
ANALOG INPUT2 TRIP DELAY
2C5A
ANALOG INPUT2 NAME
ANALOG I/O / ANALOG INPUT 3
2C80
ANALOG INPUT3
2C85
ANALOG INPUT3 UNITS
2C88
ANALOG INPUT3 MINIMUM
2C8A
ANALOG INPUT3 MAXIMUM
2C8C
BLOCK ANALOG INPUT3 FROM ONLINE
2C8D
ANALOG INPUT3 ALARM
2C8E
ASSIGN ALARM RELAYS (2-5)
2C8F
ANALOG INPUT3 ALARM LEVEL
2C91
ANALOG INPUT3 ALARM PICKUP
2C92
ANALOG INPUT3 ALARM DELAY
2C93
ANALOG INPUT3 ALARM EVENTS
2C94
ANALOG INPUT3 TRIP
2C95
ASSIGN TRIP RELAYS (1-4)
2C96
ANALOG INPUT3 TRIP LEVEL
2C98
ANALOG INPUT3 TRIP PICKUP
2C99
ANALOG INPUT3 TRIP DELAY
2C9A
ANALOG INPUT3 NAME
ANALOG I/O / ANALOG INPUT 4
2CC0
ANALOG INPUT4
2CC5
ANALOG INPUT4 UNITS
2CC8
ANALOG INPUT4 MINIMUM
2CCA
ANALOG INPUT4 MAXIMUM
2CCC
BLOCK ANALOG INPUT4 FROM ONLINE
2CCD
ANALOG INPUT4 ALARM
2CCE
ASSIGN ALARM RELAYS (2-5)
2CCF
ANALOG INPUT4 ALARM LEVEL
2CD1
ANALOG INPUT4 ALARM PICKUP
2CD2
ANALOG INPUT4 ALARM DELAY
2CD3
ANALOG INPUT4 ALARM EVENTS
2CD4
ANALOG INPUT4 TRIP
2CD5
ASSIGN TRIP RELAYS (1-4)
2CD6
ANALOG INPUT4 TRIP LEVEL
2CD8
ANALOG INPUT4 TRIP PICKUP
2CD9
ANALOG INPUT4 TRIP DELAY
2CDA
ANALOG INPUT4 NAME
489 TESTING / SIMULATION MODE
2D00
SIMULATION MODE
2D01
PRE-FAULT TO FAULT TIME DELAY
489 TESTING / PRE-FAULT SETUP
2D20
PRE-FAULT Iphase OUTPUT
2D21
PRE-FAULT VOLTAGES PHASE-N
2D22
PRE-FAULT CURRENT LAGS VOLTAGE
2D23
PRE-FAULT Iphase NEUTRAL
2D24
PRE-FAULT CURRENT GROUND
2D25
PRE-FAULT VOLTAGE NEUTRAL
2D26
PRE-FAULT STATOR RTD TEMP
2D27
PRE-FAULT BEARING RTD TEMP
2D28
PRE-FAULT OTHER RTD TEMP
2D29
PRE-FAULT AMBIENT RTD TEMP
2D2A
PRE-FAULT SYSTEM FREQUENCY
2D2B
PRE-FAULT ANALOG INPUT 1
2D2C
PRE-FAULT ANALOG INPUT 2
2D2D
PRE-FAULT ANALOG INPUT 3
2D2E
PRE-FAULT ANALOG INPUT 4
2D4C
PRE-FAULT STATOR RTD TEMP
2D4D
PRE-FAULT BEARING RTD TEMP
2D4E
PRE-FAULT OTHER RTD TEMP
2D4F
PRE-FAULT AMBIENT RTD TEMP
489 TESTING / FAULT SETUP
2D80
FAULT Iphase OUTPUT
2D81
FAULT VOLTAGES PHASE-N
2D82
FAULT CURRENT LAGS VOLTAGE
1, 2, 3
See Table footnotes on page 6–33
GE Multilin
RANGE
0 to 1
1 to 3000
0 to 12
0 to 3
0 to 6
–50000 to 50000
–50000 to 50000
0 to 5000
0 to 2
1 to 4
–50000 to 50000
0 to 1
1 to 3000
0 to 1
0 to 2
0 to 3
–50000 to 50000
0 to 1
1 to 3000
0 to 12
0 to 3
0 to 6
–50000 to 50000
–50000 to 50000
0 to 5000
0 to 2
1 to 4
–50000 to 50000
0 to 1
1 to 3000
0 to 1
0 to 2
0 to 3
–50000 to 50000
0 to 1
1 to 3000
0 to 12
0 to 3
0 to 300
0 to 2000
0 to 150
0 to 359
0 to 2000
0 to 2000
0 to 1000
–50 to 250
–50 to 250
–50 to 250
–50 to 250
50 to 900
0 to 100
0 to 100
0 to 100
0 to 100
–50 to 250
–50 to 250
–50 to 250
–50 to 250
0 to 2000
0 to 150
0 to 359
489 Generator Management Relay
6.3 MODBUS MEMORY MAP
STEP
UNITS
FORMAT
1
F130
1
s
F2
1
F22
1
F129
1
F22
1
Units
F12
1
Units
F12
1
s
F1
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F105
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F22
1
F129
1
F22
1
Units
F12
1
Units
F12
1
s
F1
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F105
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F22
1
F138
1
s
F1
× CT
1
F3
1
× Rated
F3
1
°
F1
1
× CT
F3
1
× CT
F3
1
Volts
F2
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
Hz
F2
1
%
F1
1
%
F1
1
%
F1
1
%
F1
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
× CT
F3
1
× Rated
F3
1
°
F1
DEFAULT
0
1
_
0
_
0
100
0
0
16
10
0
1
0
0
1
20
0
1
_
0
_
0
100
0
0
16
10
0
1
0
0
1
6
20
0
1
_
0
15
0
100
0
0
0
0
40
40
40
40
600
0
0
0
0
40
40
40
40
0
100
0
6-31