GE 489 Instruction Manual page 189

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (SHEET 18 OF 24)
ADDR NAME
26A5
RTD #11 TRIP
26A6
RTD #11 TRIP VOTING
26A7
ASSIGN TRIP RELAYS (1-4)
26A8
RTD #11 TRIP TEMPERATURE
26A9
RTD #11 NAME
RTD TEMPERATURE / RTD #12
26E0
RTD #12 APPLICATION
26E1
RTD #12 ALARM
26E2
ASSIGN ALARM RELAYS (2-5)
26E3
RTD #12 ALARM TEMPERATURE
26E4
RTD #12 ALARM EVENTS
26E5
RTD #12 TRIP
26E6
RTD #12 TRIP VOTING
26E7
ASSIGN TRIP RELAYS (1-4)
26E8
RTD #12 TRIP TEMPERATURE
26E9
RTD #12 NAME
RTD TEMPERATURE / OPEN RTD SENSOR
2720
OPEN RTD SENSOR ALARM
2721
ASSIGN ALARM RELAYS (2-5)
2722
OPEN RTD SENSOR ALARM EVENTS
RTD TEMPERATURE / RTD SHORT/LOW TEMP
2740
RTD SHORT/LOW TEMP ALARM
2741
ASSIGN ALARM RELAYS (2-5)
2742
RTD SHORT/LOW TEMP ALARM EVENTS
THERMAL MODEL / MODEL SETUP
2800
ENABLE THERMAL MODEL
2801
OVERLOAD PICKUP LEVEL
2802
UNBALANCE BIAS K FACTOR
2803
COOL TIME CONSTANT ONLINE
2804
COOL TIME CONSTANT OFFLINE
2805
HOT/COLD SAFE STALL RATIO
2806
ENABLE RTD BIASING
2807
RTD BIAS MINIMUM
2808
RTD BIAS CENTER POINT
2809
RTD BIAS MAXIMUM
280A
SELECT CURVE STYLE
280B
STANDARD OVERLOAD CURVE NUMBER
TIME TO TRIP AT 1.01 × FLA
280C
280E
TIME TO TRIP AT 1.05 × FLA
2810
TIME TO TRIP AT 1.10 × FLA
TIME TO TRIP AT 1.20 × FLA
2812
2814
TIME TO TRIP AT 1.30 × FLA
TIME TO TRIP AT 1.40 × FLA
2816
TIME TO TRIP AT 1.50 × FLA
2818
281A
TIME TO TRIP AT 1.75 × FLA
TIME TO TRIP AT 2.00 × FLA
281C
281E
TIME TO TRIP AT 2.25 × FLA
2820
TIME TO TRIP AT 2.50 × FLA
TIME TO TRIP AT 2.75 × FLA
2822
2824
TIME TO TRIP AT 3.00 × FLA
2826
TIME TO TRIP AT 3.25 × FLA
TIME TO TRIP AT 3.50 × FLA
2828
282A
TIME TO TRIP AT 3.75 × FLA
282C
TIME TO TRIP AT 4.00 × FLA
TIME TO TRIP AT 4.25 × FLA
282E
2830
TIME TO TRIP AT 4.50 × FLA
2832
TIME TO TRIP AT 4.75 × FLA
TIME TO TRIP AT 5.00 × FLA
2834
2836
TIME TO TRIP AT 5.50 × FLA
TIME TO TRIP AT 6.00 × FLA
2838
283A
TIME TO TRIP AT 6.50 × FLA
283C
TIME TO TRIP AT 7.00 × FLA
TIME TO TRIP AT 7.50 × FLA
283E
2840
TIME TO TRIP AT 8.00 × FLA
2842
TIME TO TRIP AT 10.0 × FLA
TIME TO TRIP AT 15.0 × FLA
2844
1, 2, 3
See Table footnotes on page 6–33
GE Multilin
RANGE
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 2
1 to 4
0 to 1
0 to 2
1 to 4
0 to 1
0 to 1
101 to 125
0 to 12
0 to 500
0 to 500
1 to 100
0 to 1
0 to 250
0 to 250
0 to 250
0 to 2
1 to 15
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
489 Generator Management Relay
6.3 MODBUS MEMORY MAP
STEP
UNITS
FORMAT
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F115
1
F50
1
F105
1
F115
1
F50
1
F105
1
F103
× FLA
1
F3
1
F1
1
min
F1
1
min
F1
1
F3
1
F103
1
°C
F1
1
°C
F1
1
°C
F1
1
F142
1
F1
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
DEFAULT
0
11
1
90
_
3
0
16
60
0
0
12
1
80
_
0
16
0
0
16
0
0
101
0
15
30
100
0
40
130
155
6
0
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6-27