GE 489 Instruction Manual page 180

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6.3 MODBUS MEMORY MAP
Table 6–1: 489 MEMORY MAP (SHEET 9 OF 24)
ADDR NAME
DIGITAL INPUTS / GENERAL INPUT F
12B0
ASSIGN DIGITAL INPUT
12B1
ASSERTED DIGITAL INPUT STATE
12B2
INPUT NAME
12B8
BLOCK INPUT FROM ONLINE
12B9
GENERAL INPUT F CONTROL
12BA
PULSED CONTROL RELAY DWELL TIME
12BB
ASSIGN CONTROL RELAYS (1-5)
12BC
GENERAL INPUT F CONTROL EVENTS
12BD
GENERAL INPUT F ALARM
12BE
ASSIGN ALARM RELAYS (2-5)
12BF
GENERAL INPUT F ALARM DELAY
12C0
GENERAL INPUT F ALARM EVENTS
12C1
GENERAL INPUT F TRIP
12C2
ASSIGN TRIP RELAYS (1-4)
12C3
GENERAL INPUT F TRIP DELAY
DIGITAL INPUTS / GENERAL INPUT G
12D0
ASSIGN DIGITAL INPUT
12D1
ASSERTED DIGITAL INPUT STATE
12D2
INPUT NAME
12D8
BLOCK INPUT FROM ONLINE
12D9
GENERAL INPUT G CONTROL
12DA
PULSED CONTROL RELAY DWELL TIME
12DB
ASSIGN CONTROL RELAYS (1-5)
12DC
GENERAL INPUT G CONTROL EVENTS
12DD
GENERAL INPUT G ALARM
12DE
ASSIGN ALARM RELAYS (2-5)
12DF
GENERAL INPUT G ALARM DELAY
12E0
GENERAL INPUT G ALARM EVENTS
12E1
GENERAL INPUT G TRIP
12E2
ASSIGN TRIP RELAYS (1-4)
12E3
GENERAL INPUT G TRIP DELAY
DIGITAL INPUTS / REMOTE RESET
1300
ASSIGN DIGITAL INPUT
DIGITAL INPUTS / TEST INPUT
6
1310
ASSIGN DIGITAL INPUT
DIGITAL INPUTS / THERMAL RESET
1320
ASSIGN DIGITAL INPUT
DIGITAL INPUTS / DUAL SETPOINTS
1340
ASSIGN DIGITAL INPUT
1341
ACTIVE SETPOINT GROUP
1342
EDIT SETPOINT GROUP
DIGITAL INPUTS / SEQUENTIAL TRIP
1360
ASSIGN DIGITAL INPUT
1361
SEQUENTIAL TRIP TYPE
1362
ASSIGN TRIP RELAYS (1-4)
1363
SEQUENTIAL TRIP LEVEL
1365
SEQUENTIAL TRIP DELAY
DIGITAL INPUTS / FIELD-BKR DISCREP.
1380
ASSIGN DIGITAL INPUT
1381
FIELD STATUS CONTACT
1382
ASSIGN TRIP RELAYS (1-4)
1383
FIELD-BKR DISCREP. TRIP DELAY
DIGITAL INPUTS / TACHOMETER
13A0
ASSIGN DIGITAL INPUT
13A1
RATED SPEED
13A2
TACHOMETER ALARM
13A3
ASSIGN ALARM RELAYS (2-5)
13A4
TACHOMETER ALARM SPEED
13A5
TACHOMETER ALARM DELAY
13A6
TACHOMETER ALARM EVENTS
13A7
TACHOMETER TRIP
13A8
ASSIGN TRIP RELAYS (1-4)
13A9
TACHOMETER TRIP SPEED
13AA
TACHOMETER TRIP DELAY
1, 2, 3
See Table footnotes on page 6–33
6-18
RANGE
0 to 7
0 to 1
0 to 12
0 to 5000
0 to 1
0 to 250
0 to 4
0 to 1
0 to 2
1 to 4
1 to 50000
0 to 1
0 to 2
0 to 3
1 to 50000
0 to 7
0 to 1
0 to 12
0 to 5000
0 to 1
0 to 250
0 to 4
0 to 1
0 to 2
1 to 4
1 to 50000
0 to 1
0 to 2
0 to 3
1 to 50000
0 to 7
0 to 7
0 to 7
0 to 7
0 to 1
0 to 1
0 to 7
0 to 1
0 to 3
2 to 99
2 to 1200
0 to 7
0 to 1
0 to 3
1 to 5000
0 to 7
100 to 3600
0 to 2
1 to 4
101 to 175
1 to 250
0 to 1
0 to 2
0 to 3
101 to 175
1 to 250
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
F210
1
F131
1
F22
1
s
F1
1
F105
1
s
F2
1
F50
1
F105
1
F115
1
F50
1
s
F2
1
F105
1
F115
1
F50
1
s
F2
1
F210
1
F131
1
F22
1
s
F1
1
F105
1
s
F2
1
F50
1
F105
1
F115
1
F50
1
s
F2
1
F105
1
F115
1
F50
1
s
F2
1
F210
1
F210
1
F210
1
F210
1
F118
1
F118
1
F210
1
F206
1
F50
1
× Rated MW
F14
1
s
F2
1
F210
1
F109
1
F50
1
s
F2
1
F210
1
RPM
F1
1
F115
1
F50
1
%Rated
F1
1
s
F1
1
F105
1
F115
1
F50
1
%Rated
F1
1
s
F1
DEFAULT
0
0
_
0
0
0
0
0
0
16
50
0
0
1
50
0
0
_
0
0
0
0
0
0
16
50
0
0
1
50
0
0
0
0
0
0
0
0
1
5
10
0
0
1
10
0
3600
0
16
110
1
0
0
1
110
1