Table 6–1: 489 MEMORY MAP (SHEET 16 OF 24)
ADDR NAME
POWER ELEMENTS / LOW FORWARD POWER
2280
BLOCK LOW FWD POWER FROM ONLINE
2281
LOW FORWARD POWER ALARM
2282
ASSIGN ALARM RELAYS (2-5)
2283
LOW FWD POWER ALARM LEVEL
2285
LOW FWD POWER ALARM DELAY
2286
LOW FWD POWER ALARM EVENTS
2287
LOW FORWARD POWER TRIP
2288
ASSIGN TRIP RELAYS (1-4)
2289
LOW FWD POWER TRIP LEVEL
228B
LOW FWD POWER TRIP DELAY
RTD TEMPERATURE / RTD TYPES
2400
STATOR RTD TYPE
2401
BEARING RTD TYPE
2402
AMBIENT RTD TYPE
2403
OTHER RTD TYPE
RTD TEMPERATURE / RTD #1
2420
RTD #1 APPLICATION
2421
RTD #1 ALARM
2422
ASSIGN ALARM RELAYS (2-5)
2423
RTD #1 ALARM TEMPERATURE
2424
RTD #1 ALARM EVENTS
2425
RTD #1 TRIP
2426
RTD #1 TRIP VOTING
2427
ASSIGN TRIP RELAYS (1-4)
2428
RTD #1 TRIP TEMPERATURE
2429
RTD #1 NAME
RTD TEMPERATURE / RTD #2
2460
RTD #2 APPLICATION
2461
RTD #2 ALARM
2462
ASSIGN ALARM RELAYS (2-5)
2463
RTD #2 ALARM TEMPERATURE
2464
RTD #2 ALARM EVENTS
2465
RTD #2 TRIP
2466
RTD #2 TRIP VOTING
2467
ASSIGN TRIP RELAYS (1-4)
2468
RTD #2 TRIP TEMPERATURE
2469
RTD #2 NAME
RTD TEMPERATURE / RTD #3
24A0
RTD #3 APPLICATION
24A1
RTD #3 ALARM
24A2
ASSIGN ALARM RELAYS (2-5)
24A3
RTD #3 ALARM TEMPERATURE
24A4
RTD #3 ALARM EVENTS
24A5
RTD #3 TRIP
24A6
RTD #3 TRIP VOTING
24A7
ASSIGN TRIP RELAYS (1-4)
24A8
RTD #3 TRIP TEMPERATURE
24A9
RTD #3 NAME
RTD TEMPERATURE / RTD #4
24E0
RTD #4 APPLICATION
24E1
RTD #4 ALARM
24E2
ASSIGN ALARM RELAYS (2-5)
24E3
RTD #4 ALARM TEMPERATURE
24E4
RTD #4 ALARM EVENTS
24E5
RTD #4 TRIP
24E6
RTD #4 TRIP VOTING
24E7
ASSIGN TRIP RELAYS (1-4)
24E8
RTD #4 TRIP TEMPERATURE
24E9
RTD #4 NAME
RTD TEMPERATURE / RTD #5
2520
RTD #5 APPLICATION
2521
RTD #5 ALARM
2522
ASSIGN ALARM RELAYS (2-5)
2523
RTD #5 ALARM TEMPERATURE
2524
RTD #5 ALARM EVENTS
1, 2, 3
See Table footnotes on page 6–33
GE Multilin
RANGE
0 to 15000
0 to 2
1 to 4
2 to 99
2 to 1200
0 to 1
0 to 2
0 to 3
2 to 99
2 to 1200
0 to 3
0 to 3
0 to 3
0 to 3
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
489 Generator Management Relay
6.3 MODBUS MEMORY MAP
STEP
UNITS
FORMAT
1
s
F1
1
F115
1
F50
× Rated MW
1
F14
1
s
F2
1
F105
1
F115
1
F50
× Rated MW
1
F14
1
s
F2
1
F120
1
F120
1
F120
1
F120
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
DEFAULT
0
0
16
5
100
0
0
1
5
200
0
0
0
0
1
0
16
130
0
0
1
1
155
_
1
0
16
130
0
0
2
6
1
155
_
1
0
16
130
0
0
3
1
155
_
1
0
16
130
0
0
4
1
155
_
1
0
16
130
0
6-25