Table 6-9 Boot Error Codes (Bxxx) - Compaq SW TL881 DLT Mini-Lib/1 Reference Manual

Compaq storageworks tl881/tl891 family minilibrary system reference guide (july 2000)
Hide thumbs Also See for SW TL881 DLT Mini-Lib/1:
Table of Contents

Advertisement

Table 6-8
Intermodule Error Codes (6xxx)
FSC
Message
6044
Invalid Com Blk Type
6045
Command Overlap
6046
No Pkts To Send
6047
Invalid Direction
6048
Master Pkt ID Bad
6060
Slave 3 Ch Init Err
6061
Slave 3 Ch Sync Err
6062
Slave 3 Ch Flash Err
FSC
Message
B001
Boot ROM CRC Error
B002
Boot RAM Test Failed
B004
Boot Comm Open Error
B005
Boot Novram Error
B006
Boot Unused Int
B007
Flash Init Error
continued
Description
A Slave inter-module process received a packet from
the Status/Message queue, but the packet's
CommBlock type was invalid.
A Slave inter-module process received a Command
from the Master inter-module process, but a
previously issued command is still being executed.
A Slave inter-module process has been requested to
send a packet to the Master inter-module process,
but the Slave inter-module process has no packets
to send.
A Slave inter-module process has received a
direction control byte from the Master inter-module
process, but the direction control byte is invalid.
An error occurred during the 3 Ch slave module
initialization.
An error occurred attempting to sync with the 3 Ch
slave module.
An error occurred attempting to flash the 3 Ch slave
module.
Table 6-9
Boot Error Codes (Bxxx)
Description
Diagnostics and Troubleshooting 6-19