Table 6-7
Power-On Error Codes (5xxx)
FSC
Message
5031
Bad Calendar Setting
5032
Bad Setting
5033
Set Density Failed
5034
Set Compression Failed
5035
DLT Timeout Error
5036
DLT Timeout Error
5037
DLT Set Bus ID Error
5038
SCSI Lock Overrides
5039
Invalid Unlock Code
503A
Auto Cleaning
5090
Slave Command Failure
continued
Description
A time or date setting obtained from the real-time
clock, which was indicated as being running,
nevertheless was determined to be invalid.
A default setting was determined to be invalid.
You chose the DLT Density menu selection, but the
chosen DLT has failed to successfully execute the
density change request.
You chose the DLT Compression menu selection, but
the chosen DLT has failed to successfully execute
the compression mode change request.
Drive communication error during a menu operation.
Drive communication error during a menu operation.
Error returned from drive when trying to set a SCSI
ID with the configure menu.
Display message only if an attempt is made to
remove a magazine while a Prevent Medium
removal is in effect.
Display message only when an invalid unlock code is
entered.
Display message only -not an error.
Error occurred sending a menu mode command to a
slave module.
Diagnostics and Troubleshooting 6-15