6-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide
Table 6-4
Control Error Codes (2xxx)
FSC
2073
2074
2075
FSC
3001
3002
3003
3004
3006
3007
3008
3009
300A
300B
continued
Message
Drive Config Error
Stow Error
Fetch Error
Motor Process Error Codes (3xxx)
Message
Picker Retries Exceeded
Picker Tach Errors
Elevator Tach Errors
Elevator Init Error
Passthru Tach Errors
DLT Timeout Error
Invalid Drive State
Door Tach Errors
Door Fault
Elev Open Tach
Description
Set if the Alternate Unload has not been selected.
This currently applies only to DLT7000's and
DLT8000's with a controller microcode revision
greater than 50.
A stow timeout error has occurred when accessing a
remote unit. Press the Enter button to reboot for
orphan cartridge recovery.
During a remote fetch operation, the remote unit
returned an error.
Table 6-5
Description
Remove from code.
TACH errors were detected during a picker
movement.
TACH errors were detected during an elevator
movement.
An elevator jam was detected during initialization.
TACH errors were detected during pass-through
elevator movement.
Communication with one of the DLT drives was
unsuccessful.. A command was issued but status
was not returned.
Currently unused.
TACH errors were detected during a door movement.
During initialization, the door was found to be in an
improper state.
Open Tach detected on elevator motor.
continued
Need help?
Do you have a question about the SW TL881 DLT Mini-Lib/1 and is the answer not in the manual?