Minilibrary Base Module Default Screen - Compaq SW TL881 DLT Mini-Lib/1 Reference Manual

Compaq storageworks tl881/tl891 family minilibrary system reference guide (july 2000)
Hide thumbs Also See for SW TL881 DLT Mini-Lib/1:
Table of Contents

Advertisement

2-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide

MiniLibrary Base Module Default Screen

The first line shows a numerical FSC. The second line shows a brief
description of the error, in place of the words, "Error Description." The third
and fourth lines contain a one- or two-line message describing the initial ERP
in place of the words shown in the Fault screen.
A list of FSC and ERP appears in Chapter 6, "Diagnostics and
Troubleshooting."
The MiniLibrary Base Modules display a different Default screen, as shown:
DLT0 Seeking
DLT1 Idle
Loader Idle
16
_ _ _ _ _ _ _ _
The example shown is a Base Module in the module 1 position. The first and
second lines of the Default screen show the status of the two drives within the
Base Module. On line 4, a rectangle appears in each position that contains a
cartridge. An underline appears at each empty slot. The numbers at the
beginning and end of line 4 represent the numbers the system has assigned to
the first and last slots of that module.
The possible status conditions of the drives are:
I
No tape
I
Idle
I
Rewinding
I
Seeking
I
Reading
I
Writing
I
Erasing
I
Cleaning
I
Unloaded
I
Loading
I
Unloading
25