Set Device Serial_Number Blade; Set Factory - HP Integrity Superdome 2 16-socket User Manual

Onboard administrator command line interface user guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

Access level/Bay level:
All
Restrictions:
The <ip address> must be in the form ###.###.###.###, where each ### ranges from
0 to 255.

SET DEVICE SERIAL_NUMBER BLADE

Command:
SET DEVICE SERIAL_NUMBER BLADE <bay number> "<serial number>"
Description:
Sets the serial number of the specified Storage, Tape, or I/O expansion blade.
Access level/Bay level:
OA Administrator
Restrictions:
Length must be 10 characters. All printable characters are permitted.
This operation cannot be performed on server blades.

SET FACTORY

Command:
SET FACTORY
Description:
Restores the Onboard Administrator to its factory defaults. The Administrator account
password does not change.
The Onboard Administrator restarts after all changes are made.
All existing settings will be lost when this operation is run.
Settings synchronization will always copy settings from the Monarch OA to other Active
OAs in a multi-enclosure complex.
If SET FACTORY is run on a non-Monarch Active OA only the settings which are not
maintained by the Monarch OA will remain at factory default.
If SET FACTORY is run on the Monarch OA the Monarch OA factory settings that are
managed by enclosure synchronization (including Administrative account settings) will
be copied to all OAs. The Administrator account password for all OAs in the complex
will be the default password identified on the Monarch OA toe tag.
If the SET FACTORY command is run on each Active OA, including the Monarch OA,
in any order will result in the same final configuration with all settings at defaults and
matching the Monarch OA.
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
None
46
General management commands

Hide quick links:

Advertisement

Table of Contents
loading