Test Fabric; Test Clocks - HP Integrity Superdome 2 16-socket User Manual

Onboard administrator command line interface user guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

The test camnet all command will execute the global CAMNet test after first checking
that there are no partitions active.
Access level/Bay level:
All
Restrictions:
The <physical location> value must be formatted as either an 8–byte hexadecimal
integer, or a long or medium hardware resource path string (short form strings are not
supported).
Must be in the Health Repository viewer.

TEST FABRIC

Command:
TEST FABRIC
Description:
Performs an active test of the complex interconnect fabric, the CAMNet manageability fabric,
the global clock distribution, and the OA links. This test detects problems resulting from
malfunctioning hardware, missing or broken cables, or from incorrect cabling. Any test failures
results in a series of hardware indictments referencing specific hardware elements encountering
problems. To view the generated indictments, see
NOTE:
before using the TEST FABRIC command.
Access level/Bay level:
All
Restrictions:
Must be in the Health Repository viewer.

TEST CLOCKS

Command:
TEST CLOCKS
Description:
The command verifies the following:
Global clock distribution to ensure that GPSM clock control registers are set appropriately
for the complex type
If there are no partitions active, the test will also actively manipulate clock generators to
ensure that the cabling is correct on multi-enclosure systems.
This test is also run as part of the test fabric command, which requires that no
partitions are active.
All clock sources are working
Each blade is receiving both complex global clock signals
Access level/Bay level:
All
162 Health Repository commands
TEST FABRIC cannot be run on an active complex. You must shut down all partitions
<physical location>
"SHOW INDICT" (page
159).