Connect Enclosure - HP Integrity Superdome 2 16-socket User Manual

Onboard administrator command line interface user guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

Restrictions:
You must be logged on to the monarch OA to perform this command.
Example:
The output for this command will depend on how the enclosures are linked.
SHOW TOPOLOGY
Detecting linked enclosures ..
Complex Topology
Complex UUID: 09USE7332000
Complex Name: ComplexOne
Rack Name: MyRack
Enc# Enclosure Name
---- ---------------
1
Enclosure11
Other linked enclosures which are not part of this complex
Foreign Complex UUID: 09USE7334000
Enc# Enclosure Name
---- ---------------
1
Enclosure21

CONNECT ENCLOSURE

Command:
CONNECT ENCLOSURE [ ACTIVE | STANDBY ] { <enclosure number> } [ RUN
<command...> ]
Description:
Creates an SSH connection to the designated OA in a remote enclosure over the internal
management network. This command is valid from any Active OA.
This command the accepts the following arguments: an optional OA role, active (the default)
or standby, the target enclosure ID and an optional remote command.
Access level/Bay level:
Any active OA
Restrictions:
None
Example:
oa_host_name> connect enclosure 2 run show blade list
Connecting to OA 1 in enclosure 2
HP Superdome Onboard Administrator
oa2_host_name> show blade list
Bay iLO Name
--- ---------------- --------------- ------ ------- ----------
1
iLO-002264fd6b66 16.119.111.8
2
iLO-00237dd51582 16.119.110.98
3
iLO-002481bc8114 16.119.111.61
20
Rack commands
Status
Local
IP Address
-------
------- --------------
OK
Yes
15.255.99.100
Status
Local
IP Address
-------
------- --------------
OK
No
15. 255.99.110
iLO IP Address
UUID
----------------
09O977MU2000
UUID
----------------
54O999MU2001
Status Power
UID Partner
OK
Off
Off
OK
Off
Off
OK
Off
Off

Hide quick links: