Indict; Show Acquit - HP Integrity Superdome 2 16-socket User Manual

Onboard administrator command line interface user guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

NOTE:
The DIMM error table for indicted DIMMs is also displayed as part of the output from the
show <memory_location> command.
Location Installation/Health History - Mon Feb 14 14:51:46 2011
--------------------------------------------------
Indictment State: Not Indicted
Requested Deconfig State: Configured
Current Deconfig State: Not available
dimm-1/8/0/9 Location: 9A
-- Install History 1 ---
Discovery: Discovery
Timestamp: Thu Feb 10 15:31:11 2011
Serial Num: EA0DB9BF
Parent Serial: MYJ84901ZH
Part Num: 9JSF12872PY
Spare Part Num: 9JSF12872PY
Manufacturer: 2C
Product Name: DDR3 DIMM
DIMM size: 1024 MB
myhost-HR>

INDICT

Command:
INDICT <physical location>
Description:
Manually indicts a specified component
Access level/Bay level:
All
Restrictions:
The <physical location> value must be formatted as either an 8–byte hexadecimal
integer, or a long or medium hardware resource path string (short form strings are not
supported).
Must be in the Health Repository viewer.

SHOW ACQUIT

Command:
FRU Type: Blade DIMM
Location: 0x0100FF0800090A74 enclosure1/blade8/cpusocket0/dimm9
Timestamp: Thu Dec 16 15:20:16 2010
Status: OK No Errors Logged.
INDICT 157