Event
Interconnect Inserted
Interconnect Thermal Status Changed
Interconnect Removed
Interconnect Power Reset
Interconnect Port Map Info
IOX Inserted
IOX Removed
IOX Fan State Changed
IOX Power Supply Inserted
IOX Power Supply Removed
LDAP Group Removed
OA System Log Cleared
OA Name Changed
OA Inserted
OA Removed
OA Takeover
nPartition State Changed
Power Supply Status Change
Power Supply Inserted
Power Supply Removed
Power Supply Redundancy Change
Power Supply Overload
Restart Event
Rack Name Change
Rack Topology
Thermal Status Change
User Removed
User Disabled
User Rights
vPar State Changed
Xbar Inserted
Xbar Removed
Xbar Power Status Change
Cause
An interconnect module was inserted into an enclosure.
The thermal status of an interconnect module changed.
An interconnect module was removed from an enclosure.
The power of an interconnect module was reset.
The port mapping information of an interconnect module was updated.
An IOX enclosure has been connected to the complex.
An IOX enclosure has been disconnected from the complex.
The status of an IOX fan has changed.
A power supply has been inserted into an IOX enclosure.
A power supply has been removed from an IOX enclosure.
A LDAP group was removed from the Onboard Administrator. If you are logged
on to the Onboard Administrator under this LDAP group, you are disconnected.
The Onboard Administrator system log was cleared.
The Onboard Administrator DNS name was changed.
A redundant Onboard Administrator was inserted into an enclosure.
A redundant Onboard Administrator was removed from an enclosure.
A redundant and active Onboard Administrator are switching roles. The Active
Onboard Administrator reboots into Standby Mode and the redundant Onboard
Administrator transitions to Active Mode.
The status of an nPartition has changed.
The status of a power supply has changed.
A power supply has been inserted.
A power supply has been removed.
The power supplies are either now redundant or are no longer redundant.
The power supplies are being asked to draw more current than they are able.
The Onboard Administrator is about to start.
The rack name stored on the enclosure was changed.
Enclosures were connected or disconnected from the enclosure link.
A thermal sensor has changed state.
A user was removed from the Onboard Administrator. If you are logged in as
this user, you are disconnected from the Onboard Administrator.
A user was disabled. If you are logged in as this user, you are disconnected
from the Onboard Administrator.
The privilege level of a user on the Onboard Administrator was changed. If you
are logged in as this user, you are disconnected from the Onboard Administrator.
You can login again with your new privilege level.
The status of a virtual partition has changed.
A Xbar Fabric module has been inserted.
A Xbar Fabric module has been removed.
The power status of an Xbar Fabric module has changed.