SET ENCLOSURE SERIAL_NUMBER

Command:
SET ENCLOSURE SERIAL_NUMBER "<serial number>"
Description:
Sets the enclosure serial number.
Access level/Bay level:
OA Administrator
Restrictions:
Must be 10 characters in length and includes all alphanumeric, underscore (_), and dash (-)
characters.

SET ENCLOSURE UID

Command:
SET ENCLOSURE UID {ON | OFF}
Description:
Turns the UID LED of the enclosure on or off.
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
None

SET IOX UID

Command:
SET IOX UID { ALL | <iox number> [{-|,}] <iox number>]} {ON | OFF}
Description:
Turns the UID LED of the specified IOX enclosures on or off.
Access level/Bay level:
OA Administrator, OA Operator, OA user
Restrictions:
You must be logged on to the monarch OA to perform this command.

SET LLF INTERVAL

Command:
SET LLF INTERVAL <seconds>
Description:
Set the Link Loss Failure Interval
Access level/Bay level:
Operator, Administrator
Restrictions:
Must have OA permission to perform this command.
SET ENCLOSURE SERIAL_NUMBER
75