To install components when the server is in a rack, follow these steps:
WARNING!
from the server prior to removing or installing server hardware.
Voltages are present at various locations within the server whenever a DC power source is
connected. This voltage is present even when the main power switch is turned off.
Failure to observe this warning can result in personal injury or damage to equipment.
NOTE:
Ensure that there is enough area (approximately 1.5 meters [5 ft.]) to fully extend the
server from the front of the rack to work on it.
To access a rack-mounted server, follow these steps:
1.
Power off and disconnect system power. Disconnect power at the DC source end of the
power cables, using the disconnect device that is part of the rack or facility power system.
2.
Label and disconnect all cables from the unit rear panel connectors.
3.
Remove or loosen the screws that fasten the server to the rack.
4.
If the server is slide-mounted, slowly pull the chassis forward (or push from the rear) to
extend the chassis from the rack. The server is fully extended when the rail clips are locked
in place. If the server is tray-mounted, the chassis is not locked in place and can fall if
extended from the rack. You must remove tray-mounted servers from the rack for internal
access.
5.
Remove the top cover. See

Removing the Server From a Rack

WARNING!
kilograms (50 lbs). Serious injury can result if this warning is not observed.
NOTE:
Ensure that there is enough area (approximately 1.5 meters [5 ft.]) to fully extend the
server from the front of the rack to work on it.
To remove the server from the rack, follow these steps:
1.
Power off and disconnect system power. Disconnect power at the DC source end of the
power cable, using the disconnect device that is part of the rack or facility power system.
2.
Label and disconnect all cables from the unit rear panel connectors.
3.
Remove or loosen the screws that fasten the server to the rack.
4.
Label and disconnect the rack or facility ground cable from the chassis rear panel
Ensure that the system is powered off and all power sources are disconnected
"Removing and Replacing the Top Cover" (page
Do not attempt to lift the server alone. The server can weight as much as 22.7
123).
(Figure
Accessing a Rack-Mounted Server
7-1).