3 Installing Additional Components

Safety Information

This chapter describes installing additional or optional hardware to your hp Integrity cx2600
Server.
Follow the procedures listed below to ensure safe handilng of components and to prevent harm
to both you and the HP Server:
Use an antistatic wrist strap and a grounding mat, such as those included in the Electrically
Conductive Field Service Grounding Kit (HP 9300-1609).
Handle accessory boards and components by the edges only. Do not touch any metal-edge
connectors or any electrical components on accessory boards.
Do not wear clothing that is subject to static charge build-up, such as wool or synthetic
materials.
WARNING!
the server before working inside the unit. Serious injury may result if this warning is not observed.

Service Tools Required

The HP Integrity cx2620 server may require one or more of the following tools for service:
Electrically Conductive Field Service Kit (P/N 9300-1609)
1/4 inch flat blade screwdriver
ACX-15 Torx screwdriver
ACX-10 Torx screwdriver
IPF CPU install tool (P/N 5069-4551—supplied with processors shipped separately)

Accessing a Rack-Mounted Server

The HP Integrity cx2600 server is designed to be rack-mounted. The following procedure explains
how to gain access to a server that is mounted in an approved rack.
WARNING!
ballast properly placed, and so on) are employed prior to extending the server.

Installing Components When the Server Is in a Rack

Power supplies, fans, and disks can be installed when the server is fully inserted into a rack.
Only front and rear access is required.
Internal components can be accessed by removing the top cover. Proceed as follows:
WARNING!
the server before working inside the unit. Serious injury may result if this warning is not observed.
NOTE:
Ensure that there is enough area (approximately 1.5 meters [5 ft.]) to fully extend the
server out the front of the rack to work on it.
1.
Turn off and disconnect the system power. Disconnect power at the DC source end of the
power cables, using the disconnect device that is part of the rack or facility power system.
2.
Label and disconnect all cables from the unit rear panel connectors.
3.
Remove or loosen (as appropriate) the screws that fasten the server to the rack.
4.
If the server is slide-mounted, slowly pull the chassis forward (or push from the rear) to
extend the chassis from the rack. The server is fully extended when the rail clips are locked
22
Installing Additional Components
Hazardous energy is present inside the HP Server. Always remove power from
Ensure that all anti-tip features (front and rear anti-tip feet installed; adequate
Hazardous energy is present inside the HP Server. Always remove power from