Management Processor Board Leds - HP Integrity cx2600 Maintenance Manual

Hp integrity cx2600 operations and maintenance guide
Hide thumbs Also See for Integrity cx2600:
Table of Contents

Advertisement

Figure 1-7 System Board LEDs
Table 1-8
lists the system board LEDs.
Table 1-8 System Board LEDs
LED
Standby (STBY)
BMC
Firmware (F/W)

Management Processor Board LEDs

There are two LEDs located on the management processor (MP) board that may be of assistance
when troubleshooting. These LEDs are located close to the rear of the server and can be viewed
through cooling holes in the rear panel of the server. The LEDs are located as shown in
and are described in
The standby LED displays the power status of the server. It is lit when power is applied (DC In
LED on either power supply is lit). If power is applied and this indicator is off, you may have to
replace the system board.
The baseboard management controller (BMC) heartbeat LED flashes whenever the BMC is active.
If this indicator is not blinking when the server is powered on (STBY LED is lit), you may have to
replace the system board.
The firmware LED lights when the boot process begins. If the server will not boot, and this LED
is off, you may have to replace the system board.
Table
1-9.
Description
Figure 1-8
Introduction
15