HP Integrity cx2600 Maintenance Manual page 71

Hp integrity cx2600 operations and maintenance guide
Hide thumbs Also See for Integrity cx2600:
Table of Contents

Advertisement

Table 4-10 Interpret Diagnostic and System LEDs (continued)
Diag 1 LED
Diag 2 LED
Red
Off
Any Other LED Status Display
12. Power off and disconnect power from the server. (If the system has shut itself down, only
disconnect power.) To power off the server and disconnect power at the cabinet or facility
power disconnect device, press the front panel Power button.
13. Install four DIMMs in the first quad.
14. To apply power, press the front panel Power button. Observe the power LED, the diagnostic
LEDs, and the system LED.
If the fault LED on the power supply is lit, replace the faulty DIMMs or the system
board.
If the front panel power LED is not lit, replace the faulty DIMMs or the system board.
For additional information, see the SEL.
To interpret the diagnostic and system LEDs, use
Table 4-1 1 Interpret Diagnostic and System LEDs
Diag 1 LED
Diag 2 LED
Green
15. Power off and disconnect power from the server. (If the system has powered off, you only
need to disconnect power.) To power off the server, and disconnect power at the cabinet or
facility power disconnect device, press the front panel Power button.
16. Install one assembly or four DIMMs.
17. To apply power to the server, press the front panel Power button. Observe the power LED,
the diagnostic LEDs, and the system LED.
If the fault LED on the power supply is lit, replace the newly installed assembly or the
system board.
If the front panel power LED is not lit, replace the newly installed assembly or the
system board.
For additional information, see the SEL.
To interpret the diagnostic and system LEDs, see
18. To build up the server, repeat steps
19. Install the top cover on the server chassis.
20. Restart the system.
Diag 3 LED
Diag 4 LED
Off
Green
Diag 3 LED
Diag 4 LED
Green
Green
Any Other LED Status Display
Step
System LED
Flashing Red
The BMC is reporting a fatal error due
to missing DIMMs. Continue with the
build up procedure.
Replace the MP card or the system
board. For additional information, see
Table 4-3 (page 58)
Table
4-11.
System LED
Green
Green or Red
When stable
For additional information, see
Table 4-3 (page
Table 4-3 (page
15,
Step
16, and
Step 17
Troubleshooting Using Offline Support Tools
Description
.
Description
Boot in progress.
58).
58).
as required.
71