Table 4-5 EFI Error and Warning Messages (continued)
Error Number
43
44
46
48
49
50
51
52
53
54
55
56
57
58
59

Event Logs for Troubleshooting Diagnostics

The System Event Log (SEL) and Forward Progress Log (FPL), Live Event Log, and Boot logs
are available via the MP. The SEL records system events that are of major importance to system
operations. All entries for the SEL are forwarded to the FPL. The FPL contains system events,
forward progress messages from the BMC, and status/error messages from system firmware,
EFI, and from the operating system. The Live Event and Boot Logs record operating events as
they occur.

Accessing the Logs Through the MP

The MP interface provides diagnostic and configuration capabilities. To access your MP interface,
perform the following steps:
1.
If necessary, press Ctrl+B to access the MP interface.
2.
Log in with proper username and password.
3.
Select cl to display the console logs. This log displays console history from oldest to newest.
4.
Select sl to display the system logs. The system logs consist of:
System event
Forward progress
Current boot
64
Troubleshooting
Message
At least one (1) CPU is overclocked
Monarch changed to lowest stepping CPU
CPUs loaded in wrong order
SAL NVM cleared
EFI NVM cleared
EFI NVM failed
CPU deconfigured by SAL_B
A ROM revision is inconsistent with FIT or
REVBLOCK
Error building S MBIOS
Failure constructing the EFI Memory Data Table
(MDT)
UUID error
Error reading CPU S MBUS information ROM
Error accessing CRU information
Checksum error accessing CRU information
CRU information version error
Description/Solution
Check processor installation and match CPU part
numbers. CPUs must be identical.
Check processor installation and match CPU part
numbers. CPUs must be identical.
Reload processors in the correct order.
Information only, no action required.
Information only, no action required.
Reboot the server. If the error message is repeated,
contact the HP Support Center for assistance.
Check and verify processor installation. Replace
the processor that was deconfigured.
One or more firmware components (FW, BMC,
MP) is out of date. Update firmware as
appropriate.
Contact the HP Support Center for assistance.
Contact the HP Support Center for assistance.
Update with the sysset command.
Reboot the server. If the error message is repeated,
replace the failing processor.
Replace the CRU that was reported. If the error
message is repeated, contact the HP Support
Center for assistance.
Replace the CRU that was reported. If the error
message is repeated, contact the HP Support
Center for assistance.
Contact the HP Support Center for assistance.