Key Beeps

This setting determines whether or not selected
touchpads beep when their buttons are pressed.
This feature is usually turned off for a touchpad
that is located in or near bedrooms, to avoid dis-
turbing sleeping persons.
Freeze Temp
This setting determines the temperature point that
the Energy Saver Module detects a potential
freeze (heating failure) condition. The adjustable
range is from 40° to 90°F.
Temperature
This setting lets you adjust the Energy Saver
Module (ESM) room temperature setting to
match the premises thermostat. The adjustable
range is from 40°–90°F.
Note
To ensure accuracy, wait at least 15 minutes
before setting the ESM temperature to allow the
ESM to warm or cool to actual room temperature.
Cellular System
This setting determines the cellular transmis-
sion system (A or B) used for cellular commu-
nication. This information is provided by the
cellular provider based on installation ZIP code.
Concord Ultra
Acc. Modules--Bus Device-Unit ID-Keypad Options (Default = on)
¾
1.
2.
3.
Acc. Modules--Bus Device-Unit ID-Energy Options (Default = 42°F)
¾
1.
2.
3.
Acc. Modules--Bus Device-Unit ID-Energy Options (Default = none)
¾
To change the ESM Temperature setting:
1.
With the display showing the desired bus device press #, then A or B
until the display shows
until the display shows
2.
Enter the desired temperature (40°–90° F). The display flashes the
entered selection.
3.
Press # and the display shows the new setting.
Acc. Modules--Bus Device-Unit ID-Cellular Options (Default = B)
¾
To set the Cellular System:
1.
With the display showing the desired bus device press 1, (B) or 2 (A).
The display flashes the entered selection.
2.
Press # and the display shows the new setting.
The following describes how to program the settings that appear under SNAPCARDS.
To turn Key Beeps on or off:
With the display showing the desired touchpad, press # then A or B
until the display shows
KEYPAD OPTIONS
until the display shows
KEY BEEPS OFF/ON
Press 1 (off) or 2 (on) to select the desired setting. The display flashes
the entered selection.
Press # and the display shows the new setting.
To change the Freeze Temp setting:
With the display showing the desired bus device press #, then A or B
until the display shows
ENERGY OPTIONS
until the display shows
FREEZE TEMP nn DEGREES
Enter the desired freeze temperature (40°–90° F). The display flashes
the entered selection.
Press # and the display shows the new setting.
ENERGY OPTIONS
TEMPERATURE nn DEGREES
. Next, press # then A or B
(current setting).
. Next, press # then A or B
(current setting).
. Next, press # and then A or B
(current setting).