System Wiring
Notes
Concord Ultra
Note 1
Class II power transformer must be plugged into an unswitched AC power receptacle. Do
not short the transformer terminals together. The transformer contains an internal fuse that
permanently disables the output if the terminals are shorted.
Note 2
An alphanumeric touchpad is required for on-site programming.
Note 3
Speaker terminals 7 and 8 activate only for alarms in partition 1. Use speakers with an 8-
ohm or higher impedance. When connecting two or more 8-ohm speakers, they must be
wired in series as shown in the wiring diagram. Wiring two or more 8-ohm speakers in paral-
lel can permanently damage the panel.
Note 4
Onboard outputs 1 and 2 are open-collector type rated for 200 mA maximum. Output 1
defaults to configuration number 01614 (exterior siren). Output 2 defaults to configuration
number 01710 (interior siren). Refer to panel installation instructions for all possible set-
tings.
Note 5
Zone (loop) wiring shown is an example that applies to all zones (except when zone 8 is con-
figured for 2-wire smoke detectors). Install EOL resistors across all unused zone (loop)
inputs.
Note 6
For UL Listed installations, wire multiple supervised hardwire smoke detectors (10 maxi-
mum) only as shown. Maximum 10 uA current draw per detector. Maximum 80 mA current
draw in alarm.
Note 7
Some telephones are polarity-sensitive. Green and red wires may need to be reversed.
Note 8
A maximum of two Audio Verification Modules (60-677) are allowed (partition 1 only).
Wire multiple speakers in series, and power and microphone wires in parallel. Use shielded
cable where shown in diagram to prevent cross-talk between the speaker and microphone.
Audio Verification Modules shall not be used in UL Listed installations.
Note 9
Connect multiple piezo sirens in parallel. Slim Line Hardwire Interior Siren status volume
switch settings have no effect.
Note 10
Refer to the SuperBus 2000 Energy Saver Module Installation Instructions for thermostat
wiring details.
Note 11
Wire Hardwire Module zone (loop) inputs as shown for the panel. Install EOL resistors
across all unused zone (loop) inputs. Refer to the Module Installation Instructions for com-
plete details.
Note 12
Without AC power, shutdown will occur if battery voltage falls below 10.2 VDC.
98