GE 60-960-95 Installation Instructions Manual page 90

Concord ultra
Hide thumbs Also See for 60-960-95:
Table of Contents

Advertisement

System Event
Null Trigger (used for direct control)
Fire Alarm
Police Alarm
Auxiliary Alarm
Any Audible Alarm
Silent Alarm (sensor groups 2, 3, and duress)
Any Audible or Silent Alarm
HOM Group 27, 28, 32 in Alarm
Major Trouble (phone or receiver failure)
Arming to STAY or AWAY
Arming to AWAY
AVM is Interactive (audio session in progress)
Fail-to-Communicate (panel can't call CS or pager) When the fail-to-communicate output is activated.
AVM Trip (edge)
Keychain Touchpad Star Button-Press
Smoke Power (for resetting 4-wire smoke detectors) Deactivated when hardwire smoke detectors need to be reset. 015
Exterior Siren
Interior Siren
AVM Trip (pulse)
State of System Status
Tamper Condition
Closing Report Sent
Group XX in Alarm
Sensor XX in Alarm
Sensor XX Open
85
Table B3: System Event Trigger Numbers
Activated only by schedule or direct command.
When Fire sirens are started.
When Police sirens are started.
When Auxiliary sirens are started.
When any of the above sirens are started.
When a sensor in group 2 or 3 goes into alarm or when a
duress alarm is activated (does not include groups 25, 27, 28,
or 32).
When any alarm is started (does not include groups 25, 27, 28,
or 32).
When a sensor in group 27, 28, or 32 goes into alarm.
When a receiver failure (S94) or a phone failure (S96) occurs.
When the panel is armed to level 2 or 3.
When the panel is armed to level 3.
When the central station operator begins listening or talking to
the premises.
When an AVM alarm occurs, output is activated momentarily.
When the star button on a keychain touchpad is pressed.
Activated for police or fire alarms.
Activation follows all system noises
When an AVM alarm occurs, output is deactivated for 10 ms
Follows the state of system status (ready or trouble).
When any tamper is tripped
When a closing report has been successfully transmitted to the
central station.
When any sensor in group XX goes into alarm
When sensor number XX goes into alarm
When sensor number XX is opened
Table B4: Sensor Group Event Trigger Numbers
Sensor Group
Group 00 in alarm
Group 01 in alarm
Group 02 in alarm
Group 03 in alarm
Group 04 in alarm
Group 05 in alarm
Group 06 in alarm
Group 07 in alarm
Description
Trigger No.
Sensor Group
064
Group 17 in alarm
065
Group 18 in alarm
066
Group 19 in alarm
067
Group 20 in alarm
068
Group 21 in alarm
069
Group 22 in alarm
070
Group 23 in alarm
071
Group 24 in alarm
Trigger
No.
000
001
002
003
004
005
006
007
008
009
010
011
012
013
014
016
017
018
019
020
021
Table B4
Table B4
Table B4
Trigger No.
081
082
083
084
085
086
087
088
Concord Ultra

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Concord ultra

Table of Contents