Note
Although the panel voice
prompts you through pro-
gramming, it is not neces-
sary to wait for the complete
message before pressing
the next button in the pro-
gramming sequence.
Note
For all UL listed systems,
Option 1 must be on
(added).
Simon Security System
Numbered Options
Numbered options let you customize system operation according to dealer and user
needs.
The "Numbered Options" table in Appendix B lists all system options and their char-
acteristics. Fill in the last column of the table before programming to help speed up the
programming process.
There are two ways to reach the desired option setting.
Press Add or Delete, then press Option # repeatedly until you hear the option you
want changed.
Or—
Press Add or Delete, Option #, then enter the option number using the numbered
keys.
The following instructions use the last method.
Option 01: Panel Piezo Beeps (Default = On)
Determines whether the panel piezo produces beeps based on system activity (on) or is
silent (off). The following table describes all possible beeps.
Activity
ARM Doors & Windows
ARM Motion Sensors
ARM Doors/Windows &
Motion Sensors
DISARM
CHIME DOORS
CHIME SPECIAL MOTION
Trouble Beeps
No Activity
¾ To turn on Panel Piezo Beeps, press:
Add—Option #—01—DONE.
¾ To turn off Panel Piezo Beeps, press:
Delete—Option #—01—DONE.
Panel Piezo Beeps
Piezo Beep Response
Exit Delay—2 beeps sound every 5 seconds and 2
times per second during the last 10 seconds.
Silent Exit—2 beeps sound at the beginning of the
exit delay and 2 more sound just before the exit
delay expires.
Entry Delay—2 beeps sound every 5 seconds and 2
times per second during the last 10 seconds.
Exit Delay—3 beeps sound every 5 seconds and 3
times per second during the last 10 seconds.
Silent Exit—3 beeps sound at the beginning of the
exit delay and 3 more sound just before the exit
delay expires.
Entry Delay—3 beeps sound every 5 seconds and 3
times per second during the last 10 seconds.
Exit Delay—4 beeps sound every 5 seconds and 4
times per second during the last 10 seconds.
Silent Exit—4 beeps sound at the beginning of the
exit delay and 4 more sound just before the exit
delay expires.
Entry Delay—4 beeps sound every 5 seconds and 4
times per second during the last 10 seconds.
1 beep
2 beeps (when programmed)
3 beeps (when programmed)
6 beeps every minute. Press SYSTEM STATUS to
stop beeps for 4 hours.
20 beeps every minute for 5 minutes (when pro-
grammed)