Feature
Problem
Module temperature does not match actual room temperature.
Automation Module
Module is not controlling or communicating with the panel and panel indicates a "
the Automation Module bus unit number.
Module is not controlling or communicating with the panel and panel indicates a "
is the Automation Module bus unit number.
Module is not controlling or communicating with the panel and panel does not indicate a bus failure.
Cellular Backup Module
Cellular backup report does not occur.
The panel indicates "auxiliary phone trouble 1."
The panel indicates "auxiliary phone trouble 2."
The panel indicates "auxiliary phone trouble 3."
The panel indicates "auxiliary phone trouble 4."
The panel indicates "auxiliary phone trouble 5."
The panel indicates "auxiliary phone trouble 6."
SuperBus 2000 Wireless Gateway Module
73
1.
Check that the module is wired correctly to the panel terminals.
2.
Verify the module LED is flashing continuously. If the LED is not flashing, remove power and
check wiring.
3.
There is a 5-minute delay after the module returns control to the furnace/AC thermostat, before
the module overrides the thermostat again. Wait 5-minutes and try again.
The module room temperature setting has not been adjusted or was adjusted before the module
warmed or cooled to room temperature. To ensure accuracy, wait at least 15 minutes after installing
the module before adjusting the temperature. To adjust the module room temperature setting, see
TEMPERATURE under the ACCESSORY MODULES—BUS DEVICES—UNIT-ID—ENERGY OPTIONS menu in
the section "Programming the Panel."
1.
Check that the module is wired correctly to the panel terminals.
2.
Verify the SuperBus Module's red LED is flashing continuously. If the LED is not flashing,
remove power and check wiring.
1.
Check that the RS-232 cable is firmly connected to the Automation Module and Automation
Device.
2.
Verify the Automation Device is powered and turned on.
1.
Verify the Automation Module is learned on the bus.
2.
Make sure another Automation or Gateway Module isn't learned into the panel's memory. Con-
cord Ultra panels support only one Automation or Gateway Module.
1.
Verify the Cellular Backup option is on for the CS phone number being tested.
2.
Verify that the module is learned on the bus.
3.
Check that the Cellular Backup Module has been activated as outlined in the device Installation
Instructions.
1.
Check the antenna connection.
2.
Adjust the antenna positioning for maximum signal.
3.
Verify Cellular System setting.
4.
Check that the Cellular Backup Module has been activated as outlined in the device Installation
Instructions.
1.
Check the antenna connection.
2.
Adjust the antenna positioning for maximum signal.
3.
Verify Cellular System setting.
1.
Check the antenna connection.
2.
Adjust the antenna positioning for maximum signal.
Contact the cellular provider for details.
Contact the cellular provider for details.
Replace the module.
Action/Solution
BUS FAILURE UNIT nn
BUS FAILURE UNIT AMnn
" where nn is
" where nn
Concord Ultra