GE 60-960-95 Installation Instructions Manual page 42

Concord ultra
Hide thumbs Also See for 60-960-95:
Table of Contents

Advertisement

Next Phone Test (0303)
This setting is used by the Auto Phone Test feature (see
) to determine when the next automatic phone
OPTIONS—GLOBAL
test should occur. This setting should be the same as, or less than,
the Phone Test Freq. setting.
Note
For UL 1635 listed installations, this feature must be set to 1.
Output Trip Time (0304)
This setting determines how long outputs
are activated when tripped (if they are con-
figured for a momentary response).
Activity Timeout (0305)
This setting determines when the system sends a "no
activity" report. The panel can be set to wait from 1–
42 hours. If no user interaction or device activation
occurs in that time, the panel sends a report to the
central station.
Daylight Saving (0306)
When this setting is on, the panel clock automati-
cally adjusts for daylight saving time changes.
Entry Delay (partition 1: 0310, partition 2: 0320)
This setting determines how much time the user has to dis-
arm the system (after entering the armed premises through a
"designated delay door") without causing an alarm.
Note
For residential UL Listed installations, the Entry Delay must be
set to 45 seconds or less. The combined time for the Entry Delay
and Dialer Abort Delay (02006) must not exceed 60 seconds.
Exit Delay (partition 1: 0311, partition 2: 0321)
This setting determines how much time the user has (after
arming the system) to leave the premises through a "desig-
nated delay door" without causing an alarm.
Note
For UL 1023 listed installations, this feature must be set to 60
seconds or less.
37
PHONE
¾
To set the Output Trip Time:
1.
With the display showing
the number of seconds (1–12). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
¾
1.
2.
¾
1.
2.
The following sections describe the timer settings that appear under
¾
To set the Next Phone Test:
1.
With the display showing
(current setting), enter the number of days (1–255).
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
OUTPUT TRIP TIME nn SECS
To set the Activity Timeout:
With the display showing
setting), enter the number of hours (1–42). The display flashes the
entered setting.
Press # and the display shows the new setting.
To turn Daylight Saving off or on:
With the display showing
DAYLIGHT SAVING OFF/ON
ting), press 1 (off) or 2 (on). The display flashes the entered setting.
Press # and the display shows the new setting.
Timers-Partition 1-2 (Default = 30 sec.)
¾
To set the Entry Delay:
1.
With the display showing
setting), enter the desired time value (30–240 using 8-sec-
ond intervals). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Timers-Partition 1-2 (Default = 60 sec.)
¾
To set the Exit Delay:
1.
With the display showing
setting), enter the desired time value (45–184 using 8-sec-
ond intervals). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Timers-Global (Default = 7 days)
NEXT PHONE TEST nnn DAYS
Timers-Global (Default 4 sec.)
(current setting), enter
Timers-Global (Default = 24 hours)
ACTIVITY TIMEOUT nn HOURS
Timers-Global (Default = on)
(current set-
.
PARTITION 1-2
ENTRY DELAY nnn SECS
EXIT DELAY nnn SECS
(current
(current
(current
Concord Ultra

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Concord ultra

Table of Contents